A cylindrical capacitor ionization source was used in conjunction with corona discharge charge reduction for generation of singly charged ions for mass spectrometric analysis. The source consists of a fused-silica capillary threaded with a platinum wire and placed inside a stainless steel tube. Application of an electric potential to the wire results in the production of a linear stream of charged droplets when an aqueous solution is pumped through the capillary. Subsequent solvent evaporation yields ions, providing a continuous ion source for mass spectrometry. passage of the ions through a corona discharge charge reduction chamber permits reduction of the charge state to predominantly singly charged species, facilitating analysis of DNA and protein mixtures. The change from production of multiply charged ions to production of singly charged ions is extremely simple, requiring only modulation of the voltage applied to the corona discharge electrode. A simple technique for construction of the ionization source is reported. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:401 / 405
页数:5
相关论文
共 10 条
[1]   Analysis of oligonucleotides by HPLC-electrospray ionization mass spectrometry [J].
Apffel, A ;
Chakel, JA ;
Fischer, S ;
Lichtenwalter, K ;
Hancock, WS .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1320-1325
[2]   ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - CORONA DISCHARGE ION-SOURCE FOR USE IN LIQUID CHROMATOGRAPH MASS SPECTROMETER-COMPUTER ANALYTICAL SYSTEM [J].
CARROLL, DI ;
DZIDIC, I ;
STILLWELL, RN ;
HAEGELE, KD ;
HORNING, EC .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2369-2373
[3]   Corona discharge in charge reduction electrospray mass spectrometry [J].
Ebeling, DD ;
Westphall, MS ;
Scalf, M ;
Smith, LM .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5158-5161
[4]   Comment on the cylindrical capacitor electrospray interface [J].
König, S ;
Fales, HM .
ANALYTICAL CHEMISTRY, 1998, 70 (20) :4453-4455
[5]   Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification [J].
Krutchinsky, AN ;
Zhang, WZ ;
Chait, BT .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (06) :493-504
[6]   Atmospheric pressure matrix assisted laser desorption/ionization mass spectrometry [J].
Laiko, VV ;
Baldwin, MA ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :652-657
[8]   Charge reduction electrospray mass spectrometry [J].
Scalf, M ;
Westphall, MS ;
Smith, LM .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :52-60
[9]   Controlling charge states of large ions [J].
Scalf, M ;
Westphall, MS ;
Krause, J ;
Kaufman, SL ;
Smith, LM .
SCIENCE, 1999, 283 (5399) :194-197
[10]   Ionization within a cylindrical capacitor: Electrospray without an externally applied high voltage [J].
Wang, HL ;
Hackett, M .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :205-212