A coverslip method for controlled parallel sample introduction into arrays of (sub)nanoliter wells for quantitative analysis

被引:12
作者
Moerman, R [1 ]
van Dedem, GWK [1 ]
机构
[1] Delft Univ Technol, Dept Biotechnol, Kluyver Lab Biotechnol, NL-2628 BC Delft, Netherlands
关键词
D O I
10.1021/ac020432n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a straightforward coverslip method that combines rapid sample introduction into arrays of 19.8-55.0-mum-deep microwells (prefilled with reactants) on a chip with complete sealing of these wells to avoid evaporation during optical detection. We used coverslips of 300-1500-mum-thick poly(methyl methacrylate) (PMMA) containing arrays of holes with diameters of 200 and 300 mum, and 800-mum-thick quartz slides containing arrays of holes with diameters of 100 and 200 mum. A coverslip was placed on top of a chip, thereby positioning the holes between the wells. A defined amount of aqueous sample solution was pulled between the cover and silicon nitride coated chip by means of capillary forces, resulting in entrapment of air in all wells. By partly or completely positioning the holes over the wells, air could escape through the holes, resulting in complete filling of the wells with the surrounding liquid within 0.1-0.2 s. Immediately after filling, the slide was rapidly shifted back to its original position and was pressed onto the chip for 5-30 s with a force of 1-2 kg cm(-2), resulting in complete sealing of the wells for minutes up to one-half hour. Because the well volumes of an array are identical and the wells are completely filled, reproducible assay volumes and flat menisci are obtained, making this method very suitable for quantitative analysis.
引用
收藏
页码:4132 / 4138
页数:7
相关论文
共 19 条
[1]   High-density oligonucleotide arrays [J].
Blanchard, AP ;
Kaiser, RJ ;
Hood, LE .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (6-7) :687-690
[2]   ELECTROCHEMICAL MEASUREMENTS IN SUBMICROLITER VOLUMES [J].
BOWYER, WJ ;
CLARK, ME ;
INGRAM, JL .
ANALYTICAL CHEMISTRY, 1992, 64 (04) :459-462
[3]   Micromachining sensors for electrochemical measurement in subnanoliter volumes [J].
Bratten, CDT ;
Cobbold, PH ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :253-258
[4]   Electrochemical analysis in picoliter microvials [J].
Clark, RA ;
Hietpas, PB ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :259-263
[5]   DIFFUSIONAL MICROTITRATION - ACID-BASE TITRATIONS IN PICOLITER AND FEMTOLITER SAMPLES [J].
GRATZL, M ;
YI, C .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2085-2088
[6]   Characterisation of an antibody coated microcantilever as a potential immuno-based biosensor [J].
Grogan, C ;
Raiteri, R ;
O'Connor, GM ;
Glynn, TJ ;
Cunningham, V ;
Kane, M ;
Charlton, M ;
Leech, D .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) :201-207
[7]   Manual manufacturing of oligonucleotide, DNA, and protein microchips [J].
Guschin, D ;
Yershov, G ;
Zaslavsky, A ;
Gemmell, A ;
Shick, V ;
Proudnikov, D ;
Arenkov, P ;
Mirzabekov, A .
ANALYTICAL BIOCHEMISTRY, 1997, 250 (02) :203-211
[8]   ON-COLUMN AND POSTCOLUMN DERIVATIZATION FOR CAPILLARY ELECTROPHORESIS WITH LASER-INDUCED FLUORESCENCE FOR THE ANALYSIS OF SINGLE CELLS [J].
HIETPAS, PB ;
EWING, AG .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (18-19) :3557-3576
[9]   Fabricating large arrays of microwells with arbitrary dimensions and filling them using discontinuous dewetting [J].
Jackman, RJ ;
Duffy, DC ;
Ostuni, E ;
Willmore, ND ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (11) :2280-2287
[10]   A new method for the immobilisation of antibodies in conducting polymers [J].
Korri-Youssoufi, H ;
Richard, C ;
Yassar, A .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2001, 15 (1-2) :307-310