Preparation of nano-sized Pb2+ imprinted polymer and its application as the chemical interface of an electrochemical sensor for toxic lead determination in different real samples

被引:93
作者
Alizadeh, Taher [1 ]
Amjadi, Somaye [1 ]
机构
[1] Univ Mohaghegh Ardabili, Fac Sci, Dept Appl Chem, Ardebil 5619911367, Iran
关键词
Pb2+; Imprinted polymer; Differential pulse voltammetry; Electrochemical sensor; ANODIC-STRIPPING VOLTAMMETRY; SOLID-PHASE EXTRACTION; CARBON-PASTE ELECTRODE; BISMUTH-FILM ELECTRODES; TRACE DETERMINATION; SPECTROPHOTOMETRIC DETERMINATION; PLATED CARBON; HEAVY-METALS; WATER; CADMIUM;
D O I
10.1016/j.jhazmat.2011.03.067
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work, a new nano-structured ion imprinted polymer (IIP) was synthesized by copolymerization of methacrylic acid-Pb2+ complex and ethylene glycol dimethacrylate according to the precipitation polymerization. Methacrylic acid acted as both functional monomer and complexing agent to create selective coordination sites in a cross-linked polymer. A carbon paste electrode modified with IIP-nanoparticles was used for fabrication of a Pb2+ sensitive electrode. Differential pulse stripping voltammetry method was applied as the determination technique, after open circuit sorption of Pb2+ on the electrode and its reduction to metallic form. The IIP modified electrode showed a considerably higher response, compared to the electrode embedded with non-imprinted polymer (NIP). This indicated that the suitable recognition sites were created in the IIP structure in the polymerization stage. Various factors, effective on the response behavior of the electrode, were investigated and optimized. The introduced sensor showed a linear range of 1.0 x 10(-9) to 8.1 x 10(-7) M and detection limit of 6.0 x 10(-19) M (S/N = 3). The sensor was successfully applied for the trace lead determination in different samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:451 / 459
页数:9
相关论文
共 85 条
[1]   Spectrophotometric determination of lead in industrial, environmental, biological and soil samples using 2,5-dimercapto-1,3,4-thiadiazole [J].
Ahmed, MJ ;
Mamun, MA .
TALANTA, 2001, 55 (01) :43-54
[2]   Promethazine determination in plasma samples by using carbon paste electrode modified with molecularly imprinted polymer (MIP): Coupling of extraction, preconcentration and electrochemical determination [J].
Alizadeh, Taher ;
Akhoundian, Maedeh .
ELECTROCHIMICA ACTA, 2010, 55 (20) :5867-5873
[3]   Development of a voltammetric sensor based on a molecularly imprinted polymer (MIP) for caffeine measurement [J].
Alizadeh, Taher ;
Ganjali, Mohamad Reza ;
Zare, Mashaalah ;
Norouzi, Parviz .
ELECTROCHIMICA ACTA, 2010, 55 (05) :1568-1574
[4]   A new molecularly imprinted polymer (MIP)-based electrochemical sensor for monitoring 2,4,6-trinitrotoluene (TNT) in natural waters and soil samples [J].
Alizadeh, Taher ;
Zare, Mashaalah ;
Ganjali, Mohamad Reza ;
Norouzi, Parviz ;
Tavana, Babak .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (05) :1166-1172
[5]   A novel high selective and sensitive para-nitrophenol voltammetric sensor, based on a molecularly imprinted polymer-carbon paste electrode [J].
Alizadeh, Taher ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz ;
Zare, Mashallah ;
Zeraatkar, Ali .
TALANTA, 2009, 79 (05) :1197-1203
[6]   Adsorption and Recognition Properties of Ionic Imprinted Polyamine IIP-PEI/SiO2 Towards Pb2+ Ion [J].
An, Fuqiang ;
Gao, Baojiao ;
Feng, Xiaoqin .
JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 112 (04) :2241-2246
[7]   Molecularly imprinted polymers for bioanalysis: Chromatography, binding assays and biomimetic sensors [J].
Ansell, RJ ;
Kriz, D ;
Mosbach, K .
CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) :89-94
[8]   Anodic stripping voltammetry at a new type of disposable bismuth-plated carbon paste mini-electrodes [J].
Baldrianova, L. ;
Svancara, I. ;
Sotiropoulos, S. .
ANALYTICA CHIMICA ACTA, 2007, 599 (02) :249-255
[9]   Anodic stripping voltammetry at in situ bismuth-plated carbon and gold microdisc electrodes in variable electrolyte content unstirred solutions [J].
Baldrianova, L. ;
Svancara, I. ;
Economou, A. ;
Sotiropoulos, S. .
ANALYTICA CHIMICA ACTA, 2006, 580 (01) :24-31
[10]   Direct determination of copper and lead in sewage sludge by solid sampling-graphite furnace atomic absorption spectrometry - study of the interference reduction in the gaseous phase working in non-stop flow conditions [J].
Belarra, MA ;
Crespo, C ;
Resano, M ;
Castillo, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :865-874