Novel micromachined silicon sensor for continuous glucose monitoring

被引:40
作者
Piechotta, G [1 ]
Albers, J [1 ]
Hintsche, R [1 ]
机构
[1] Fraunhofer Inst Silicon Technol, D-25524 Itzehoe, Germany
关键词
glucose sensor; micromachined silicon; continuous measurement; diffusion control; signal stability; clinical trials;
D O I
10.1016/j.bios.2005.02.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The construction and the application properties of a micromachined silicon sensor for continuous glucose monitoring are presented. The sensor uses the conventional enzymatic conversion of glucose with amperometric detection of H2O2. The innovation is the precise diffusion control of the analyte through a porous silicon membrane into a silicon etched cavity containing the immobilised enzyme. A variation of the number and size of the membrane pores allows to adjust the linear range of the sensor to the respective requirement. The sensor was tested in vitro as well as in clinical studies, being supplied with interstitial fluid. The cavity sensor was designed for a linear range between 0.5 and 20 mM. A signal response time of below 30 s and a signal stability exceeding 1 week is shown. By using a double cavity sensor falsification of the glucose signal by interfering substances can be compensated. In clinical trials the sensor measured continuously in interstitial fluid for up to 18 h without any signal drift and with good correlation to blood glucose reference values. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:802 / 808
页数:7
相关论文
共 22 条
[11]  
Mastrototaro J, 1999, J PEDIATR ENDOCR MET, V12, P751
[12]   Detection of hypoglycemia with the GlucoWatch biographer [J].
Pitzer, KR ;
Desai, S ;
Dunn, T ;
Edelman, S ;
Jayalakshmi, Y ;
Kennedy, J ;
Tamada, JA ;
Potts, RO .
DIABETES CARE, 2001, 24 (05) :881-885
[13]   A lightweight measuring device for the continuous in vivo monitoring of glucose by means of ultraslow microdialysis in combination with a miniaturised flow-through biosensor [J].
Rhemrev-Boom, RM ;
Tiessen, RG ;
Jonker, AA ;
Venema, K ;
Vadgama, P ;
Korf, J .
CLINICA CHIMICA ACTA, 2002, 316 (1-2) :1-10
[14]   GLUCOSE-CONCENTRATION IN SUBCUTANEOUS EXTRACELLULAR-SPACE [J].
SCHMIDT, FJ ;
SLUITER, WJ ;
SCHOONEN, AJM .
DIABETES CARE, 1993, 16 (05) :695-700
[15]   Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin [J].
Schmidtke, DW ;
Freeland, AC ;
Heller, A ;
Bonnecaze, RT .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (01) :294-299
[16]  
SHICHIRI M, 1984, BIOMED BIOCHIM ACTA, V43, P561
[17]   SUBCUTANEOUS GLUCOSE-CONCENTRATION IN HUMANS - REAL ESTIMATION AND CONTINUOUS MONITORING [J].
STERNBERG, F ;
MEYERHOFF, C ;
MENNEL, FJ ;
BISCHOF, F ;
PFEIFFER, EF .
DIABETES CARE, 1995, 18 (09) :1266-1269
[18]   Noninvasive glucose monitoring - Comprehensive clinical results [J].
Tamada, JA ;
Garg, S ;
Jovanovic, L ;
Pitzer, KR ;
Fermi, S ;
Potts, RO .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (19) :1839-1844
[19]   Clinical evaluation of the GlucoWatch® biographer:: a continual, non-invasive glucose monitor for patients with diabetes [J].
Tierney, MJ ;
Tamada, JA ;
Potts, RO ;
Jovanovic, L ;
Garg, S .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :621-629
[20]  
Tierney MJ, 1999, CLIN CHEM, V45, P1681