Microchip micellar electrokinetic chromatography separation of alkaloids with UV-absorbance spectral detection

被引:29
作者
Newman, Carl I. D. [1 ]
Giordan, Braden C. [2 ]
Copper, Christine L. [3 ]
Collins, Greg E. [1 ]
机构
[1] USN, Res Lab, Div Chem, Washington, DC 20375 USA
[2] NovaRes Inc, Alexandria, VA USA
[3] USN Acad, Dept Chem, Annapolis, MD 21402 USA
关键词
alkaloids; microchip; micellar electrokinetic chromatography; on-line preconcentration; spectral resolution;
D O I
10.1002/elps.200700591
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microchip device is demonstrated for the electrophoretic separation and UV-absorbance spectral detection of four toxic alkaloids: colchicine, aconitine, strychnine, and nicotine. A fused-silica (quartz) microchip containing a simple cross geometry is utilized to perform the separations, and a miniature, fiber-optic CCD spectrometer is coupled to the microchip for detection. Sensitive UV-absorbance detection is achieved via the application of online preconcentration techniques in combination with the quartz microchip substrate which contains an etched bubble-cell for increased pathlength. The miniature CCD spectrometer is configured to detect light between 190 and 645 nm and LabView programming written in-house enables absorbance spectra as well as separations to be monitored from 210 to 400 nm. Consequently, the configuration of this microchip device facilitates qualitative and quantitative separations via simultaneous spatial and spectral resolution of solutes. UV-absorbance limits of quantification for colchicine, 20 mu M (8 mg/L); strychnine, 50 mu M (17 mg/L); aconitine, 50 mu M (32 mg/L); and nicotine, 100 mu M (16 mg/L) are demonstrated on the microchip. With the exception of aconitine, these concentrations are >= 20-times more sensitive than lethal dose monitoring requirements. Finally, this device is demonstrated to successfully detect each toxin in water, skim milk, and apple juice samples spiked at sublethal dose concentrations after a simple, SPE procedure.
引用
收藏
页码:803 / 810
页数:8
相关论文
共 51 条
[1]  
ARMANDULA H, 2005, LASER INTERFEROMETER
[2]   Sample stacking revisited: A personal perspective [J].
Chien, RL .
ELECTROPHORESIS, 2003, 24 (03) :486-497
[3]   Radionuclide and metal ion detection on a capillary electrophoresis microchip using LED absorbance detection [J].
Collins, GE ;
Lu, Q .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) :244-249
[4]   Microfabricated capillary electrophoresis sensor for uranium (VI) [J].
Collins, GE ;
Lu, Q .
ANALYTICA CHIMICA ACTA, 2001, 436 (02) :181-189
[5]   Long pathlength, three-dimensional absorbance microchip [J].
Collins, Greg E. ;
Lu, Qin ;
Pereira, Nicholas ;
Wu, Peter .
TALANTA, 2007, 72 (01) :301-304
[6]   Self-poisoning with Colchicum autumnale L. flowers [J].
Danel, VC ;
Wiart, JFD ;
Hardy, GA ;
Vincent, FH ;
Houdret, NMP .
JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 2001, 39 (04) :409-411
[7]   Determination of five toxic alkaloids in two common herbal medicines with capillary electrophoresis [J].
Feng, HT ;
Li, SFY .
JOURNAL OF CHROMATOGRAPHY A, 2002, 973 (1-2) :243-247
[8]   Poisoning by plant material: review of human cases and analytical determination of main toxins by high-performance liquid chromatography-(tandem) mass spectrometry [J].
Gaillard, Y ;
Pepin, G .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 733 (1-2) :181-229
[9]   Micelle stacking in micellar electrokinetic chromatography [J].
Giordano, Braden C. ;
Newman, Carl I. D. ;
Federowicz, Philip M. ;
Collins, Greg E. ;
Burgi, Dean S. .
ANALYTICAL CHEMISTRY, 2007, 79 (16) :6287-6294
[10]   Microchip-based CEC of nitroaromatic and nitramine explosives using silica-based sol-gel stationary phases from methyl- and ethyl-trimethoxysilane precursors [J].
Giordano, Braden C. ;
Terray, Alex ;
Collins, Greg E. .
ELECTROPHORESIS, 2006, 27 (21) :4295-4302