Three post-column ion chromatographic methods (i.e., a sodium bromide-sodium nitrite method, an o-dianisidine method, and a potassium iodide-ammonium heptamolybdate method) were compared for bromate and nitrite analysis. Also, the effect of direct mixing of the reagents without ion suppressors for the sodium bromide-sodium nitrite method and the potassium iodide-ammonium heptamolybdate method was investigated. For the analysis of bromate, the three methods showed similar method detection limits (0.17-0.24 mug/l) with pneumatic reagent delivery systems. Direct reagent mixing achieved comparable detection limits to the suppressor configuration. The three methods are also compatible with conductivity detection. When used in combination with conductivity detection, this compatibility allows simultaneous analysis of bromate, nitrite, and other common ions in drinking water, such as bromide. It was found that the o-dianisidine method achieves mug/l-Ievel detection of nitrite and bromate with a simpler configuration than the potassium iodide-ammonium heptamolybdate method, while the sodium bromide-sodium nitrite method was not sufficiently sensitive for nitrite analysis at the mug/l level. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:205 / 211
页数:7
相关论文
共 19 条
[11]   Simultaneous determination of bromide, bromate and nitrite in low μg 1-1 levels by ion chromatography without sample pretreatment [J].
Salhi, E ;
von Gunten, U .
WATER RESEARCH, 1999, 33 (15) :3239-3244
[12]  
US Environmental Protection Agency, 1998, FED REGISTER, V63, P69389
[13]   Analysis of 500-ng/1 levels of bromate in drinking water by direct-injection suppressed ion chromatography coupled with a single, pneumatically delivered post-column reagent [J].
Wagner, HP ;
Pepich, BV ;
Hautman, DP ;
Munch, DJ .
JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) :119-129
[14]   A ion chromatographic method for measuring <5 mu g/L bromate ion in drinking water [J].
Walters, BD ;
Gordon, G ;
Bubnis, B .
ANALYTICAL CHEMISTRY, 1997, 69 (20) :4275-4277
[15]   New, sensitive and selective method for determining sub-μg/l levels of bromate in drinking water [J].
Weinberg, HS ;
Yamada, H ;
Joyce, RJ .
JOURNAL OF CHROMATOGRAPHY A, 1998, 804 (1-2) :137-142
[16]   Post-ion-chromatography derivatization for the determination of oxyhalides at sub-PPB levels in drinking water [J].
Weinberg, HS ;
Yamada, H .
ANALYTICAL CHEMISTRY, 1998, 70 (01) :1-6
[17]  
World Health Organization, 1993, WHO L1BR CAT 1N PUBL
[18]   Specific determination of bromate and iodate in ozonized water by ion chromatography with postcolumn derivatization and inductively-coupled plasma mass spectrometry [J].
Yamanaka, M ;
Sakai, T ;
Kumagai, H ;
Inoue, Y .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :259-265
[19]  
1994, FED REG, V59, P38709