Local detection of enzymatic ion generation with polycrystalline silicon interdigitated electrodes and its application to biosensing

被引:8
作者
de la Rica, Roberto [1 ]
Baldi, Antonio [1 ]
Fernandez-Sanchez, Cesar [1 ]
机构
[1] Esfera UAB, CSIC, CNM, IMB, E-08193 Barcelona, Spain
关键词
D O I
10.1063/1.2472718
中图分类号
O59 [应用物理学];
学科分类号
摘要
Chips containing polycrystalline silicon interdigitated electrodes are modified with the enzyme urease. The sensors are able to detect changes in the resitivity of the solution near their surface, where the enzymatic reaction generates charged species. The electrodes are also grafted with an antigen and queried with different amounts of urease labeled antibody. The response of the modified electrodes is proportional to the amount of enzyme attached to the surface by the biorecognition event, thus validating the assay for biosensing applications. (c) 2007 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 14 条
[1]   Electrical biochip technology - a tool for microarrays and continuous monitoring [J].
Albers, J ;
Grunwald, T ;
Nebling, E ;
Piechotta, G ;
Hintsche, R .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) :521-527
[2]   Polysilicon interdigitated electrodes as impedimetric sensors [J].
de la Rica, Roberto ;
Fernandez-Sanchez, Cesar ;
Baldi, Antonio .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (08) :1239-1244
[3]   Disposable noncompetitive immunosensor for free and total prostate-specific antigen based on capacitance measurement [J].
Fernández-Sánchez, C ;
McNeil, CJ ;
Rawson, K ;
Nilsson, O .
ANALYTICAL CHEMISTRY, 2004, 76 (19) :5649-5656
[4]   AC voltammetric carbon paste-based enzyme immunosensors [J].
Fernández-Sánchez, C ;
González-García, MB ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (12) :917-924
[5]   Quartz crystal microbalance detection of glutathione-protected nanoclusters using antibody recognition [J].
Gerdon, AE ;
Wright, DW ;
Cliffel, DE .
ANALYTICAL CHEMISTRY, 2005, 77 (01) :304-310
[6]  
HERMANSON TJ, 1996, BIOCONJUGATE TECHNIQ, P173
[7]   SPR imaging of photo-cross-linked small-molecule arrays on gold [J].
Kanoh, N ;
Kyo, M ;
Inamori, K ;
Ando, A ;
Asami, A ;
Nakao, A ;
Osada, H .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2226-2230
[8]   Optical fiber immunosensor based on a poly(pyrrole-benzophenone) film for the detection of antibodies to viral antigen [J].
Konry, T ;
Novoa, A ;
Shemer-Avni, Y ;
Hanuka, N ;
Cosnier, S ;
Lepellec, A ;
Marks, RS .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1771-1779
[9]   On-chip enzyme immunoassay of a cardiac marker using a microfluidic device combined with a portable surface plasmon resonance system [J].
Kurita, Ryoji ;
Yokota, Yoshimi ;
Sato, Yukari ;
Mizutani, Fumio ;
Niwa, Osamu .
ANALYTICAL CHEMISTRY, 2006, 78 (15) :5525-5531
[10]   Model of an immobilized enzyme conductimetric urea biosensor [J].
Sheppard, NF ;
Mears, DJ ;
GuiseppiElie, A .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (10) :967-979