Open-flow microperfusion of subcutaneous adipose tissue for on-line continuous ex vivo measurement of glucose concentration

被引:55
作者
Trajanoski, Z
Brunner, GA
Schaupp, L
Ellmerer, M
Wach, P
Pieber, TR
Kotanko, P
Skrabal, F
机构
[1] KARL FRANZENS UNIV GRAZ, DEPT INTERNAL MED, GRAZ, AUSTRIA
[2] KRANKENHAUS BARMHERZIGEN BRUDER, DEPT INTERNAL MED, GRAZ, AUSTRIA
关键词
D O I
10.2337/diacare.20.7.1114
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To evaluate a novel technique for on-line continuous glucose measurement in subcutaneous adipose tissue, and to investigate its accuracy for detection of hypoglycemia. RESEARCH DESIGN AND METHODS - The method combined an open-flow microperfusion of subcutaneous adipose tissue using a double lumen catheter and an extracorporeal sensor cell. An isotonic ion-free solution was perfused through the inner lumen of the catheter. equilibrated with the subcutaneous tissue fluid, and sampled through the outer lumen. The recovery was continuously monitored as the ratio between the measured sampled fluid conductivity and the subcutaneous tissue fluid conductivity (assumed to have a constant value of 1.28 S/m at 25 degrees C). Glucose concentration was calculated on-line from the measured glucose in the sampled fluid and the measured recovery in healthy volunteers during hyperglycemic glucose loads (n = 8), hypoglycemic hyperinsulinemic clamp (n = 6), and a 24-h monitoring period (n = 7). RESULTS - Subcutaneous glucose concentrations in the fasting state were 94% of the plasma glucose concentrations in arterialized venous samples. According to the error grid analysis, 96.9% of the on-line measured subcutaneous glucose concentrations during hyperglycemia and 96.3% during hypoglycemia were in accurate or acceptable zones. The mean differences between the measured subcutaneous glucose and the actual plasma glucose concentration were -0.06-3.3 mmol/l (hyperglycemia). and -0.6-1.1 mmol/l (hypoglycemia). CONCLUSIONS - By combining open-flow microperfusion, glucose sensor, and conductivity measurement. glucose concentration in the subcutaneous adipose tissue can be monitored on-line. extracorporeally and continuously without any in vivo calibration, and gives accurate measurements during hyper- and hypoglycemia.
引用
收藏
页码:1114 / 1121
页数:8
相关论文
共 42 条
  • [31] A GLUCOSE MONITORING-SYSTEM FOR ON LINE ESTIMATION IN MAN OF BLOOD-GLUCOSE CONCENTRATION USING A MINIATURIZED GLUCOSE SENSOR IMPLANTED IN THE SUBCUTANEOUS TISSUE AND A WEARABLE CONTROL UNIT
    POITOUT, V
    MOATTISIRAT, D
    REACH, G
    ZHANG, Y
    WILSON, GS
    LEMONNIER, F
    KLEIN, JC
    [J]. DIABETOLOGIA, 1993, 36 (07) : 658 - 663
  • [32] OPEN FLOW MICROPERFUSION - APPROACH TO IN-VIVO GLUCOSE MONITORING
    RIGBY, GP
    CRUMP, P
    VADGAMA, P
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (02) : 231 - 234
  • [33] GLUCOSE-CONCENTRATION IN SUBCUTANEOUS EXTRACELLULAR-SPACE
    SCHMIDT, FJ
    SLUITER, WJ
    SCHOONEN, AJM
    [J]. DIABETES CARE, 1993, 16 (05) : 695 - 700
  • [34] GLYCEMIC THRESHOLDS FOR ACTIVATION OF GLUCOSE COUNTERREGULATORY SYSTEMS ARE HIGHER THAN THE THRESHOLD FOR SYMPTOMS
    SCHWARTZ, NS
    CLUTTER, WE
    SHAH, SD
    CRYER, PE
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1987, 79 (03) : 777 - 781
  • [35] CLOSED-LOOP GLYCEMIC CONTROL WITH A WEARABLE ARTIFICIAL ENDOCRINE PANCREAS - VARIATIONS IN DAILY INSULIN REQUIREMENTS TO GLYCEMIC RESPONSE
    SHICHIRI, M
    KAWAMORI, R
    HAKUI, N
    YAMASAKI, Y
    ABE, H
    [J]. DIABETES, 1984, 33 (12) : 1200 - 1202
  • [36] PORTABLE SYSTEM FOR ONLINE CONTINUOUS EX-VIVO MONITORING OF SUBCUTANEOUS TISSUE GLUCOSE USING OPEN TISSUE PERFUSION
    SKRABAL, F
    TRAJANOSKI, Z
    KONTSCHEIDER, H
    KOTANKO, P
    WACH, P
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (01) : 116 - 118
  • [37] SUBCUTANEOUS GLUCOSE-CONCENTRATION IN HUMANS - REAL ESTIMATION AND CONTINUOUS MONITORING
    STERNBERG, F
    MEYERHOFF, C
    MENNEL, FJ
    BISCHOF, F
    PFEIFFER, EF
    [J]. DIABETES CARE, 1995, 18 (09) : 1266 - 1269
  • [38] STERNBERG R, 1988, BIOSENSORS, V4, P27
  • [39] MEASUREMENT OF GLUCOSE IN DIABETIC SUBJECTS USING NONINVASIVE TRANSDERMAL EXTRACTION
    TAMADA, JA
    BOHANNON, NJV
    POTTS, RO
    [J]. NATURE MEDICINE, 1995, 1 (11) : 1198 - 1201
  • [40] Accuracy of home blood glucose meters during hypoglycemia
    Trajanoski, Z
    Brunner, GA
    Gfrerer, RJ
    Wach, P
    Pieber, TR
    [J]. DIABETES CARE, 1996, 19 (12) : 1412 - 1415