Electroanalytical determination of cadmium(II) and lead(II) using an in-situ bismuth film modified edge plane pyrolytic graphite electrode

被引:103
作者
Kachoosangi, Roohollah Torabi [1 ]
Banks, Craig E. [1 ]
Ji, Xiaobo [1 ]
Compton, Richard G. [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, S Parks Rd, Oxford OX1 3QZ, England
关键词
D O I
10.2116/analsci.23.283
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and simple electroanalytical methodology is presented using an in-situ bismuth film modified edge plane pyrolytic graphite electrode (BiF-EPPGE) which is exemplified with the simultaneous determination of cadmium(II) and lead(II). Square-wave anodic stripping voltammetry is utilised with the effects of several experimental variables studied. Simultaneous additions of cadmium(II) and lead(II) were investigated where two linear ranges between 0.1 - 100 and 0.1 - 300 mu g/L and also detection limits of 0.062 and 0.084 mu g/L were obtained, respectively. The method was then successfully applied to the simultaneous determination of cadmium(II) and lead(II) in spiked river water, where recoveries of 100.5 and 98% were obtained, respectively. This electroanalytical protocol using edge plane pyrolytic graphite electrodes is one of the simplest methodologies to date using non-mercury based electrodes and is simpler and cheaper than alternatives such as carbon nanotube electrode arrays, suggesting the use of edge plane pyrolytic graphite electrode for routine sensing.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 67 条
[1]   Bismuth film microelectrodes for heavy metals monitoring by anodic stripping voltammetry [J].
Baldo, MA ;
Daniele, S ;
Bragato, C .
JOURNAL DE PHYSIQUE IV, 2003, 107 :103-106
[2]   New electrodes for old: from carbon nanotubes to edge plane pyrolytic graphite [J].
Banks, CE ;
Compton, RG .
ANALYST, 2006, 131 (01) :15-21
[3]   Edge plane pyrolytic graphite electrodes in electroanalysis: An overview [J].
Banks, CE ;
Compton, RG .
ANALYTICAL SCIENCES, 2005, 21 (11) :1263-1268
[4]   Manganese detection in marine sediments:: anodic vs. cathodic stripping voltammetry [J].
Banks, CE ;
Kruusma, J ;
Moore, RR ;
Tomcík, P ;
Peters, J ;
Davis, J ;
Komorsky-Lovric, S ;
Compton, RG .
TALANTA, 2005, 65 (02) :423-429
[5]   Sonoelectroanalysis: investigation of bismuth-film-modified glassy carbon electrodes [J].
Banks, CE ;
Kruusma, J ;
Hyde, ME ;
Salimi, A ;
Compton, RG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (02) :277-282
[6]   Cadmium detection via boron-doped diamond electrodes:: surfactant inhibited stripping voltarnmetry [J].
Banks, CE ;
Hyde, ME ;
Tomcík, P ;
Jacobs, R ;
Compton, RG .
TALANTA, 2004, 62 (02) :279-286
[7]   RAPID ANODIC-STRIPPING ANALYSIS WITH ULTRAMICROELECTRODES [J].
BARANSKI, AS .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :662-666
[8]   Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: Optimum conditions and reliability [J].
Belmont, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
KoudelkaHep, M .
ANALYTICA CHIMICA ACTA, 1996, 329 (03) :203-214
[9]  
CARIDADE CG, 2006, ELECTROANAL, V18, P854
[10]   Sensitive stripping voltammetry of heavy metals by using a composite sensor based on a built-in bismuth precursor [J].
Castañeda, MT ;
Pérez, B ;
Pumera, M ;
del Valle, M ;
Merkoçi, A ;
Alegret, S .
ANALYST, 2005, 130 (06) :971-976