Thoracoabdominal-aortoiliac MDCT angiography using reduced dose of contrast material

被引:21
作者
Kubo, Shigeto
Tadamura, Eiji
Yamamuro, Masaki
Hosokawa, Ryohei
Kimura, Takeshi
Kita, Toru
Komeda, Masashi
Togashi, Kaori
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Kyoto Univ, Grad Sch Med, Dept Nucl Med & Diagnost Imaging, Kyoto, Japan
[3] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Kyoto, Japan
[4] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Surg, Kyoto, Japan
关键词
cardiovascular imaging; contrast media; saline flush; MDCT angiography;
D O I
10.2214/AJR.05.0309
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to compare the image quality of MDCT angiography studies obtained by injection of low doses of contrast medium with saline flush versus conventional doses of contrast medium. MATERIALS AND METHODS. Seventy-one patients with pre- or postoperative aortic aneurysms underwent MDCT angiography throughout the thoracoabdominal-aortoiliac system using an 8-MDCT scanner. In 37 patients, 100 mL of contrast medium was injected at a flow rate of 3.0 mL/s (hereafter referred to as the 100-mL group). In 34 patients, 50 mL of contrast medium followed by a 20-mL saline flush was injected at a flow rate of 2.5 mL/s (the 50-mL group). For each group, quantitative analysis involved calculating the mean aortoiliac enhancement, plateau deviation, and contrast enhancement in the pulmonary trunk and superior vena cava (SVC). Qualitative analysis involved assessing the 3D postprocessing images. RESULTS. Significant differences between the groups in mean aortoiliac enhancement (100-mL group vs 50-mL group, 337 +/- 6 H vs 319 +/- 5 H, p < 0.0001) and mean plateau deviation (51 +/- 4 H vs 58 +/- 4 H, p < 0.0001) were found. However, adequate arterial enhancement (>= 200 H) was observed in 31 of 34 patients in the 50-mL group and uniform aortoiliac enhancement (< 50 H) was seen in 26 patients. Visual analysis showed no difference in contrast material magnitude and homogeneity between the groups. Furthermore, in the 50-mL group, the thoracic aorta was more clearly visualized because of a reduction in the opacity of the main pulmonary artery and SVC. CONCLUSION. In our experience, administration of 50 mL of contrast medium followed by a 20-mL saline flush produces thoracoabdominal-aortoiliac MDCT angiographic examinations of effective quality in most cases.
引用
收藏
页码:548 / 554
页数:7
相关论文
共 26 条
[1]   Aortic aneurysmal disease: Assessment of stent-graft treatment - CT versus conventional angiography [J].
Armerding, MD ;
Rubin, GD ;
Beaulieu, CF ;
Slonim, SM ;
Olcott, EW ;
Samuels, SL ;
Jorgensen, MJ ;
Semba, CP ;
Jeffrey, RB ;
Dake, MD .
RADIOLOGY, 2000, 215 (01) :138-146
[2]   Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT [J].
Awai, K ;
Inoue, M ;
Yagyu, Y ;
Watanabe, M ;
Sano, T ;
Nin, S ;
Koike, R ;
Nishimura, Y ;
Yamashita, Y .
RADIOLOGY, 2004, 233 (03) :682-688
[3]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[4]   Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT [J].
Awai, K ;
Hori, S .
EUROPEAN RADIOLOGY, 2003, 13 (09) :2155-2160
[5]   Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[6]   Contrast agent-associated nephrotoxicity [J].
Briguori, C ;
Tavano, D ;
Colombo, A .
PROGRESS IN CARDIOVASCULAR DISEASES, 2003, 45 (06) :493-503
[7]   Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax [J].
Haage, P ;
Schmitz-Rode, T ;
Hübner, D ;
Piroth, W ;
Günther, RW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :1049-1053
[8]   Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector [J].
Hopper, KD ;
Mosher, TJ ;
Kasales, CJ ;
TenHave, TR ;
Tully, DA ;
Weaver, JS .
RADIOLOGY, 1997, 205 (01) :269-271
[9]   Renal artery stenosis: Detection and quantification with spiral CT angiography versus optimized digital subtraction angiography [J].
Kaatee, R ;
Beek, FJA ;
deLange, EE ;
vanLeeuwen, MS ;
Smits, HFM ;
vanderVen, PJG ;
Beutler, JJ ;
Mali, WPTM .
RADIOLOGY, 1997, 205 (01) :121-127
[10]   Contrast nephropathy: An evidence-based approach to prevention [J].
David E. Kandzari ;
Abdallah G. Rebeiz ;
Andrew Wang ;
Michael H. Sketch .
American Journal of Cardiovascular Drugs, 2003, 3 (6) :395-405