Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients

被引:224
作者
Wolthaus, Jochem W. H. [1 ]
Schneider, Christoph [1 ]
Sonke, Jan-Jakob [1 ]
van Herk, Marcel [1 ]
Belderbos, Jose S. A. [1 ]
Rossi, Maddalena M. G. [1 ]
Lebesque, Joos V. [1 ]
Damen, Eugene M. F. [1 ]
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 65卷 / 05期
关键词
computed tomography; four-dimensional; respiration-correlated; breathing; treatment planning; lung cancer; mid-ventilation;
D O I
10.1016/j.ijrobp.2006.04.031
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Four-dimensional (4D) respiration-correlated imaging techniques can be used to obtain (respiration) artifact-free computed tomography (CT) images of the thorax. Current radiotherapy planning systems, however, do not accommodate 4D-CT data. The purpose of this study was to develop a simple, new concept to incorporate patient-specific motion information, using 4D-CT scans, in the radiotherapy planning process of lung cancer patients to enable smaller error margins. Methods and Materials: A single CT scan was selected from the 4D-CT data set. This scan represented the tumor in its time-averaged position over the respiratory cycle (the mid-ventilation CT scan). To select the appropriate CT scan, two methods were used. First, the three-dimensional tumor motion was analyzed semiautomatically to calculate the mean tumor position and the corresponding respiration phase. An alternative automated method was developed to select the correct CT scan using the diaphragm motion. Results: Owing to hysteresis, mid-ventilation selection using the three-dimensional tumor motion had a tumor position accuracy (with respect to the mean tumor position) better than 1.1 +/- 1.1 mm for all three directions (inhalation and exhalation). The accuracy in the diaphragm motion method was better than 1.1 +/- 1.1 mm. Conventional free-breathing CT scanning had an accuracy better than 0 +/- 3.9 mm. The mid-ventilation concept can result in an average irradiated volume reduction of 20% for tumors with a diameter of 40 mm. Conclusion: Tumor motion and the diaphragm motion method can be used to select the (artifact-free) mid-ventilation CT scan, enabling a significant reduction of the irradiated volume. (c) 2006 Elsevier Inc.
引用
收藏
页码:1560 / 1571
页数:12
相关论文
共 41 条
[31]   Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer [J].
Underberg, RWM ;
Lagerwaard, FJ ;
Slotman, BJ ;
Cuijpers, JP ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (01) :253-260
[32]   Definition of gross tumor volume in lung cancer: inter-observer variability [J].
Van de Steene, J ;
Linthout, N ;
de Mey, J ;
Vinh-Hung, V ;
Claassens, C ;
Noppen, M ;
Bel, A ;
Storme, G .
RADIOTHERAPY AND ONCOLOGY, 2002, 62 (01) :37-49
[33]   Errors and margins in radiotherapy [J].
van Herk, M .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :52-64
[34]   Biologic and physical fractionation effects of random geometric errors [J].
van Herk, M ;
Witte, M ;
van Der Geer, J ;
Schneider, C ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (05) :1460-1471
[35]   Inclusion of geometric uncertainties in treatment plan evaluation [J].
van Herk, M ;
Remeijer, P ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (05) :1407-1422
[36]  
VANHERK M, 2000, ICCR 13 HEID GERM, P73
[37]   Acquiring a four-dimensional computed tomography dataset using an external respiratory signal [J].
Vedam, SS ;
Keall, PJ ;
Kini, VR ;
Mostafavi, H ;
Shukla, HP ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (01) :45-62
[38]   The effects of target size and tissue density on the minimum margin required for random errors [J].
Witte, MG ;
van der Geer, J ;
Schneider, C ;
Lebesque, JV ;
van Herk, M .
MEDICAL PHYSICS, 2004, 31 (11) :3068-3079
[39]   Fusion of respiration-correlated PET and CT scans: correlated lung tumour motion in anatomical and functional scans [J].
Wolthaus, JWH ;
van Herk, M ;
Muller, SH ;
Belderbos, JSA ;
Lebesque, JV ;
de Bois, JA ;
Rossi, MMG ;
Damen, EMF .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (07) :1569-1583
[40]   The use of active breathing control (ABC) to reduce margin for breathing motion [J].
Wong, JW ;
Sharpe, MB ;
Jaffray, DA ;
Kini, VR ;
Robertson, JM ;
Stromberg, JS ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (04) :911-919