Dual-Source versus 64-Section CT Coronary Angiography at Lower Heart Rates: Comparison of Accuracy and Radiation Dose

被引:45
作者
Baumueller, Stephan [1 ]
Leschka, Sebastian [1 ]
Desbiolles, Lotus [1 ]
Stolzmann, Paul [1 ]
Scheffel, Hans [1 ]
Seifert, Burkhardt [2 ]
Marincek, Borut [1 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Inst Social & Prevent Med, Biostat Unit, CH-8006 Zurich, Switzerland
关键词
SPIRAL COMPUTED-TOMOGRAPHY; STABLE ANGINA-PECTORIS; DIAGNOSTIC-ACCURACY; ARTERY-DISEASE; IMAGE QUALITY; RATE-VARIABILITY; NONINVASIVE DETECTION; 1ST EXPERIENCE; ROW CT; PERFORMANCE;
D O I
10.1148/radiol.2531090065
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the diagnostic performance and radiation doses of dual-source and 64-section computed tomographic (CT) coronary angiography for the diagnosis of significant coronary stenoses in patients with heart rates of 65 beats/min or less. Materials and Methods: This retrospective study had local ethics committee approval; all patients gave written informed consent. Two hundred patients with heart rates of 65 beats/min or less were enrolled; 100 underwent dual-source and 100 underwent 64-section CT coronary angiography. Two blinded observers independently assessed image quality of all coronary segments by using a four-point scale and searched for significant (>50%) stenoses in each segment. Catheter angiography was used as the reference standard. Image noise was measured in the ascending aorta. Radiation doses were calculated. Results: No significant differences were found regarding sex, age, body weight, cardiovascular risk profile, prevalence of stenosis, mean and variability of heart rate, Agatston score, and image noise (all P>.1) between patients in both CT coronary angiography groups. No significant difference was found in the rate of nonassessable coronary segments between dual-source (1.0%, 14 of 1405) and 64-section CT coronary angiography (1.8%, 25 of 1387; P = .08). Motion artifacts occurred significantly more often in 64-section (21 of 25) versus dual-source (five of 14, P = .004) CT coronary angiography. Segment-based accuracy and specificity were significantly higher for dual-source versus 64-section CT coronary angiography. There was no significant difference in accuracy parameters at the per-vessel and per-patient analyses. No significant difference (P = .13) was found between the effective doses of dual-source ( mean +/- standard deviation, 10.9 mSv +/- 1.1) and 64-section CT (10.4 mSv +/- 1.7) coronary angiography. Conclusion: In patients with heart rates of 65 beats/min or less, the higher temporal resolution of dual-source CT coronary angiography results in improved accuracy and specificity for the diagnosis of significant stenoses on a per-segment level at a similar radiation dose, but provides a comparable diagnostic accuracy on a patient-based level as does 64-section coronary angiography. (C) RSNA, 2009
引用
收藏
页码:56 / 64
页数:9
相关论文
共 40 条
[21]   Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability [J].
Matt, David ;
Scheffel, Hans ;
Leschka, Sebastian ;
Flohr, Thomas G. ;
Marincek, Borut ;
Kaufmann, Philipp A. ;
Alkadhi, Hatem .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) :567-573
[22]   Dose performance of a 64-channel dual-source CT scanner [J].
McCollough, Cynthia H. ;
Primak, Andrew N. ;
Saba, Osama ;
Bruder, Herbert ;
Stierstorfer, Karl ;
Raupach, Rainer ;
Suess, Christoph ;
Schmidt, Bernhard ;
Ohnesorge, Bernd M. ;
Flohr, Thomas G. .
RADIOLOGY, 2007, 243 (03) :775-784
[23]   Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris [J].
Mollet, NR ;
Cademartiri, F ;
Nieman, K ;
Saia, F ;
Lemos, PA ;
McFadden, EP ;
Pattynama, PMT ;
Serruys, PW ;
Krestin, GP ;
de Feyter, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (12) :2265-2270
[24]   High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography [J].
Mollet, NR ;
Cademartiri, F ;
van Mieghem, CAG ;
Runza, G ;
McFadden, EP ;
Baks, T ;
Serruys, PW ;
Krestin, GP ;
de Feyter, PJ .
CIRCULATION, 2005, 112 (15) :2318-2323
[25]  
Morin R.L., 1988, MONTE CARLO SIMULATI
[26]   Accuracy of 64-MDCT in the diagnosis of ischemic heart disease [J].
Nikolaou, K ;
Knez, A ;
Rist, C ;
Wintersperger, BJ ;
Leber, A ;
Johnson, T ;
Reiser, MF ;
Becker, CR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) :111-117
[27]   β-blockers for cardiac CT:: A primer for the radiologist [J].
Pannu, HK ;
Alvarez, W ;
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :S341-S345
[28]   Relationship between noise, dose, and pitch in cardiac multi-detector row CT [J].
Primak, Andrew N. ;
McCollough, Cynthia H. ;
Bruesewitz, Michael R. ;
Zhang, Jie ;
Fletcher, Joel G. .
RADIOGRAPHICS, 2006, 26 (06) :1785-1794
[29]   Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris [J].
Pugliese, F ;
Mollet, NRA ;
Runza, G ;
van Mieghem, C ;
Meijboom, WB ;
Malagutti, P ;
Baks, T ;
Krestin, GP ;
deFeyter, PJ ;
Cademartiri, F .
EUROPEAN RADIOLOGY, 2006, 16 (03) :575-582
[30]   Diagnostic performance of coronary CT angiography by using different generations of multisection scanners: Single-center experience [J].
Pugliese, Francesca ;
Mollet, Nico R. ;
Hunink, M. G. Myriam ;
Cademartiri, Filippo ;
Nieman, Koen ;
van Domburg, Ron T. ;
Meijboom, Willem B. ;
Van Mieghem, Carlos ;
Weustink, Annick C. ;
Dijkshoorn, Marcel L. ;
de Feyter, Pim J. ;
Krestin, Gabriel P. .
RADIOLOGY, 2008, 246 (02) :384-393