Preliminary characterization and fundamental properties of aerosols generated by a flow focusing pneumatic nebulizer

被引:22
作者
Almagro, B
Gañán-Calvo, AM
Canals, A
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, E-03080 Alicante, Spain
[2] Univ Sevilla, Escuela Super Ingn, E-41092 Seville, Spain
关键词
D O I
10.1039/b400502n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new pneumatic concentric nebulizer (flow focusing pneumatic nebulizer, FFPN), based on the capillary flow focusing effect which produces highly controllable. ne aerosols, is presented for the first time for analytical applications. The key aerosol diagnostic data and analytical figures of merit obtained using ICP-AES are presented for the FFPN and compared with a commercially available glass concentric nebulizer ( conical nebulizer, CK). To perform a fair comparison, both nebulizers have been run under their own standard working conditions. Under all the conditions studied, the FFPN produces a finer primary aerosol than the conventional pneumatic nebulizer. At a solution uptake rate of 2.0 mL min(-1) and a nebulizer gas flow rate of 1.0 L min(-1) for the CK, and at a solution uptake rate of 0.2 mL min(-1) and a nebulizer gas flow rate of 0.7 L min(-1) for the FFPN, the median diameter (D-50) values of the primary aerosol are 24.64 mum and 3.82 mum with the CK and FFPN, respectively. The tertiary aerosols of the CK and FFPN studied do not show a substantial difference, the D-50 values, under the same operating conditions stated above, being 2.89 mum and 2.87 mum for the CK and FFPN, respectively. Under most of the studied conditions, all the primary aerosols produced by FFPN are contained on droplets smaller than 10 mm. For example, under the above experimental conditions, nearly 22% and 98% of primary aerosol volume is contained on droplets having sizes less than 10 mm for the CK and FFPN, respectively. However, approximately all the tertiary aerosol volume is contained on droplets smaller than this diameter with both nebulizers. This is the result of strong filtering action of the cyclonic spray chamber used, with a cut-off diameter of 15 mum, when CK is used. In general, sensitivities, precision and limits of detection with the FFPN are similar or better than those of the CK, yet with a sample uptake rate of only one-tenth the CK rate.
引用
收藏
页码:1340 / 1346
页数:7
相关论文
共 41 条
[31]   Acid effects in inductively coupled plasma atomic emission spectrometry with different nebulizers operated at very low sample consumption rates [J].
Todoli, JL ;
Mermet, JM ;
Canals, A ;
Hernandis, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (01) :55-62
[32]   Comparison of characteristics and limits of detection of pneumatic micronebulizers and a conventional nebulizer operating at low uptake rates in ICP-AES -: Invited lecture [J].
Todolí, JL ;
Hernandis, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1289-1295
[33]  
Todoli JL, 1997, QUIM ANAL, V16, P177
[34]   Evaluation of a direct injection high-efficiency nebulizer (DIHEN) by comparison with a high-efficiency nebulizer (HEN) coupled to a cyclonic spray chamber as a liquid sample introduction system for ICP-AES [J].
Todolí, JL ;
Mermet, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) :514-520
[35]   CHARACTERIZATION OF A NEW SINGLE-BORE HIGH-PRESSURE PNEUMATIC NEBULIZER FOR ATOMIC SPECTROMETRY .1. DROP SIZE DISTRIBUTION, TRANSPORT VARIABLES AND ANALYTICAL SIGNAL IN FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
TODOLI, JL ;
CANALS, A ;
HERNANDIS, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (03) :373-386
[36]   PERFORMANCE OF THE NEW SINGLE-BORE HIGH-PRESSURE PNEUMATIC NEBULIZER (SBHPPN) IN PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
TODOLI, JL ;
MUNOZ, M ;
VALIENTE, M ;
HERNANDIS, V ;
CANALS, A .
APPLIED SPECTROSCOPY, 1994, 48 (05) :573-580
[37]   Evaluation of a commercially available microconcentric nebulizer for inductively coupled plasma mass spectrometry [J].
Vanhaecke, F ;
VanHolderbeke, M ;
Moens, L ;
Dams, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (08) :543-548
[38]  
WANG L, 1998, Patent No. 5725153
[39]   Axial inductively coupled plasma time-of-flight mass spectrometry using direct liquid sample introduction [J].
Westphal, CS ;
McLean, JA ;
Acon, BW ;
Allen, LA ;
Montaser, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (07) :669-675
[40]   DIRECT INJECTION NEBULIZATION FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
WIEDERIN, DR ;
SMITH, FG ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :219-225