Single camera based spectral domain polarization sensitive optical coherence tomography

被引:68
作者
Baumann, Bernhard [1 ]
Goetzinger, Erich [1 ]
Pircher, Michael [1 ]
Hitzenberger, Christoph K. [1 ]
机构
[1] Med Univ vienna, Ctr Biomed Eng & Phys, A-1090 Vienna, Austria
来源
OPTICS EXPRESS | 2007年 / 15卷 / 03期
基金
奥地利科学基金会;
关键词
D O I
10.1364/OE.15.001054
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We developed a new spectral domain polarization sensitive optical coherence tomography (SD PS-OCT) system that requires only a single spectrometer CCD camera. The spectra of the horizontal and vertical polarization channels are imaged adjacent to each other on a 2048 pixel line scan camera, using 1024 pixels for each channel. Advantages of the system are reduced costs and complexity, lower demands on timing and triggering circuitry, and higher robustness against camera misalignments. We discuss the additional postprocessing required to accommodate for spectral distortions, show calibration measurements in a test sample, and finally demonstrate the system for measuring human ocular tissue in vivo. (c) 2007 Optical Society of America.
引用
收藏
页码:1054 / 1063
页数:10
相关论文
共 31 条
[11]  
Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI 10.2184/lsj.31.635
[12]   High speed spectral domain polarization sensitive optical coherence tomography of the human retina [J].
Götzinger, E ;
Pircher, M ;
Hitzenberger, CK .
OPTICS EXPRESS, 2005, 13 (25) :10217-10229
[13]  
Götzinger E, 2003, P SOC PHOTO-OPT INS, V5140, P120, DOI 10.1117/12.500662
[14]   POLARIZATION-SENSITIVE LOW-COHERENCE REFLECTOMETER FOR BIREFRINGENCE CHARACTERIZATION AND RANGING [J].
HEE, MR ;
HUANG, D ;
SWANSON, EA ;
FUJIMOTO, JG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (06) :903-908
[15]   Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography [J].
Hitzenberger, CK ;
Götzinger, E ;
Sticker, M ;
Pircher, M ;
Fercher, AF .
OPTICS EXPRESS, 2001, 9 (13) :780-790
[16]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[17]  
*INT EL COM, 2001, SAF LAS PROD 1
[18]   Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography [J].
Jiao, SL ;
Wang, LHV .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (03) :350-358
[19]   Form-biattenuance in fibrous tissues measured with polarization-sensitive optical coherence tomography (PS-OCT) [J].
Kemp, NJ ;
Zaatari, HN ;
Park, J ;
Rylander, HG ;
Milner, TE .
OPTICS EXPRESS, 2005, 13 (12) :4611-4628
[20]  
Laser Institute of America, 2000, AM NAT STAND SAF US