Implanted electrochemical glucose sensors for the management of diabetes

被引:155
作者
Heller, A [1 ]
机构
[1] Univ Texas, Dept Chem Engn, Austin, TX 78712 USA
[2] Univ Texas, Texas Mat Inst, Austin, TX 78712 USA
关键词
biosensors; subcutaneous; amperometry; continuous monitoring;
D O I
10.1146/annurev.bioeng.1.1.153
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
By maintaining a near normal (70-120 mg/dL) glucose concentration, diabetic patients can drastically reduce the likelihood of the occurrence of diabetes complications. In the near future, subcutaneously implanted electrochemical glucose sensors will be available to provide frequent or continuous information on which timely treatment decisions, such as insulin injection or glucose source intake, can be based, as well as timely alarm signals. The currently engineered devices are of three types: (a) innocuous microsensors, with actively mass-transporting areas <10(-3) cm(2), replaced twice a week by the patient; (b) self-contained, surgeon-implanted, transmitter-containing packages of >1 cm(2) area, operating for >100 days; and (c) devices transporting subcutaneous fluid to an external sensor, based on implanted microfiltration or microdialysis fibers or on iontophoretic transport of the subcutaneous fluid through the skin.
引用
收藏
页码:153 / 175
页数:23
相关论文
共 103 条
[41]   GLUCOSE CONTENT IN HUMAN SKIN - RELATIONSHIP WITH BLOOD-GLUCOSE LEVELS [J].
JENSEN, BM ;
BJERRING, P ;
CHRISTIANSEN, JS ;
ORSKOV, H .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1995, 55 (05) :427-432
[42]   INVIVO EVALUATION OF AN ELECTROENZYMATIC GLUCOSE SENSOR IMPLANTED IN SUBCUTANEOUS TISSUE [J].
JOHNSON, KW ;
MASTROTOTARO, JJ ;
HOWEY, DC ;
BRUNELLE, RL ;
BURDENBRADY, PL ;
BRYAN, NA ;
ANDREW, CC ;
ROWE, HM ;
ALLEN, DJ ;
NOFFKE, BW ;
MCMAHAN, WC ;
MORFF, RJ ;
LIPSON, D ;
NEVIN, RS .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (10) :709-714
[43]   COMBINATION OF MICRODIALYSIS AND GLUCOSENSOR PERMITS CONTINUOUS (ON LINE) SC GLUCOSE MONITORING IN A PATIENT OPERATED DEVICE .1. INVITRO EVALUATION [J].
KECK, FS ;
KERNER, W ;
MEYERHOFF, C ;
ZIER, H ;
PFEIFFER, EF .
HORMONE AND METABOLIC RESEARCH, 1991, 23 (12) :617-618
[44]   COMBINATION OF MICRODIALYSIS AND GLUCOSENSOR PERMITS CONTINUOUS (ON LINE) SC GLUCOSE MONITORING IN A PATIENT OPERATED DEVICE .2. EVALUATION IN ANIMALS [J].
KECK, FS ;
MEYERHOFF, C ;
KERNER, W ;
SIEGMUND, T ;
ZIER, H ;
PFEIFFER, EF .
HORMONE AND METABOLIC RESEARCH, 1992, 24 (10) :492-493
[45]   Electrochemical glucose and lactate sensors based on ''wired'' thermostable soybean peroxidase operating continuously and stably at 37 degrees C [J].
Kenausis, G ;
Chen, Q ;
Heller, A .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1054-1060
[46]  
KERNER W, 1999, IN PRESS ANAL CHEM
[47]   Noninvasive blood glucose monitoring [J].
Klonoff, DC .
DIABETES CARE, 1997, 20 (03) :433-437
[48]   INVIVO BEHAVIOR OF HYPODERMICALLY IMPLANTED MICROFABRICATED GLUCOSE SENSORS [J].
KOUDELKA, M ;
ROHNERJEANRENAUD, F ;
TERRETTAZ, J ;
BOBBIONIHARSCH, E ;
DEROOIJ, NF ;
JEANRENAUD, B .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) :31-36
[49]  
KOUDELKA M, 1989, BIOMED BIOCHIM ACTA, V48, P953
[50]   MINIATURE ELECTROCHEMICAL GLUCOSE BIOSENSORS [J].
KOUDELKAHEP, M ;
STRIKE, DJ ;
DEROOIJ, NF .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :461-466