Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography

被引:126
作者
Fischer, U [1 ]
Baum, F [1 ]
Obenauer, S [1 ]
Luftner-Nagel, S [1 ]
von Heyden, D [1 ]
Vosshenrich, R [1 ]
Grabbe, E [1 ]
机构
[1] Univ Gottingen, Dept Radiol, D-37075 Gottingen, Germany
关键词
microcalcification; full-field digital mammography; diagnostic accuracy;
D O I
10.1007/s00330-002-1354-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of this prospective study was to compare a full-field digital mammography system (FFDM) to a conventional screen-film mammography system (SFM) for the detection and characterization of microcalcifications. Fifty-five patients with 57 isolated microcalcification clusters were examined using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, Wis.) and a SFM system (Senographe DMR, GE Medical Systems, Milwaukee, Wis.). A conventional screen-film mammogram and a digital contact mammogram were obtained of each cluster. The image quality and the number of calcification particles were evaluated, and a characterization (BI-RADS 1-5) of microcalcifications was given by four experienced readers. Histopathology revealed 16 benign lesions (sclerosing adenosis, dysplasia, hamartoma, radial scar) in 15 patients and 21 malignant tumors (in situ carcinoma, invasive carcinoma) in 20 patients. Twenty patients had benign changes verified by long-term follow-up. Image quality of FFDM was assessed as superior to SFM in more than 50% of the cases. The FFDM showed more calcifications in 41% of all cases. Sensitivity and specificity for FFDM vs SFM were 95.2 vs 91.9% and 41.4 vs 39.3%, respectively. Moreover, FFDM demonstrated a higher diagnostic accuracy (deviation: 0.86 BI-RADS steps) compared with FSM (deviation 0.93 BI-RADS steps). The FFDM system with a 100-mum pixel size provides better image quality than SFM in patients with mammographic microcalcifications. The FFDM has a higher sensitivity and a higher reliability in characterizing microcalcifications.
引用
收藏
页码:2679 / 2683
页数:5
相关论文
共 17 条
  • [1] [Anonymous], BREAST IM REP DAT SY
  • [2] Full-field digital mammography
    Bick, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [3] Magnification survey and spot view mammography with a new microfocus X-ray unit: detail resolution and radiation exposure
    Funke, M
    Breiter, N
    Hermann, KP
    Oestmann, JW
    Grabbe, E
    [J]. EUROPEAN RADIOLOGY, 1998, 8 (03) : 386 - 390
  • [4] A magnification mammography technique using storage phosphor plates: Experimental investigations concerning spatial resolution and detection of microcalcifications.
    Funke, M
    Hermann, KP
    Breiter, N
    HundertMark, C
    Sachs, J
    Gruhl, T
    Sperner, W
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (02): : 174 - 179
  • [5] Grabbe E, 2001, RADIOLOGE, V41, P359, DOI 10.1007/s001170051014
  • [6] Radiation exposure in full-field digital mammography with a flat-panel x-ray detector based on amorphous silicon in comparison with conventional screen-film mammography.
    Hermann, KP
    Obenauer, S
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (11): : 940 - 945
  • [7] Digital mammography in direct magnification technique using a large-area amorphous silicon X-ray detector.
    Hermann, KP
    Hundertmark, C
    Funke, M
    von Brenndorff, A
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 503 - 506
  • [8] Storage phosphor and film-screen mammography:: performance with different mammographic techniques
    Kheddache, S
    Thilander-Klang, A
    Lanhede, B
    Månsson, LG
    Bjurstam, N
    Ackerholm, P
    Björneld, L
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (04) : 591 - 597
  • [9] Comparison of full-field digital mammography with screen-film mammography for cancer detection: Results of 4,945 paired examinations
    Lewin, JM
    Hendrick, RE
    D'Orsi, CJ
    Isaacs, PK
    Moss, LJ
    Karellas, A
    Sisney, GA
    Kuni, CC
    Cutter, GR
    [J]. RADIOLOGY, 2001, 218 (03) : 873 - 880
  • [10] Full-field digital mammography designed as a complete system
    Muller, S
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (01) : 25 - 34