Assessment of an in situ temporal calibration method for time-resolved optical tomography

被引:25
作者
Hebden, JC
Gonzalez, FM
Gibson, A
Hillman, EMC
Yusof, RM
Everdell, N
Delpy, DT
Zaccanti, G
Martelli, F
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6JA, England
[2] Univ Florence, I-50019 Sesto Fiorentino, Firenze, Italy
[3] INFM, Dipartimento Fis, I-50019 Sesto Fiorentino, Firenze, Italy
基金
英国惠康基金;
关键词
optical tomography; time-resolved; diffuse imaging;
D O I
10.1117/1.1528206
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A 32-channel time-resolved optical imaging device is developed at University College London to produce functional images of the neonatal brain and the female breast. Reconstruction of images using time-resolved measurements of transmitted light requires careful calibration of the temporal characteristics of the measurement system. Since they can often vary over a period of time, it is desirable to evaluate these characteristics immediately after, or prior to, the acquisition of image data. A calibration technique is investigated that is based on the measurement of light back-reflected from the surface of the object being imaged. This is facilitated by coupling each detector channel with an individual source fiber. A Monte Carlo model is employed to investigate the influence of the optical properties of the object on the back-reflected signal. The results of simulations indicate that their influence may be small enough to be ignored in some cases, or could be largely accounted for by a small adjustment to the calibrated data. The effectiveness of the method is briefly demonstrated by imaging a solid object with tissue-equivalent optical properties. (C) 2003 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 22 条
[11]   Time resolved optical tomography of the human forearm [J].
Hillman, EMC ;
Hebden, JC ;
Schweiger, M ;
Dehghani, H ;
Schmidt, FEW ;
Delpy, DT ;
Arridge, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :1117-1130
[12]   Calibration techniques and datatype extraction for time-resolved optical tomography [J].
Hillman, EMC ;
Hebden, JC ;
Schmidt, FEW ;
Arridge, SR ;
Schweiger, M ;
Dehghani, H ;
Delpy, DT .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (09) :3415-3427
[13]   Three-dimensional optical tomographic Imaging of breast in a human subject [J].
Jiang, H ;
Xu, Y ;
Iftimia, N ;
Eggert, J ;
Klove, K ;
Baron, L ;
Fajardo, L .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (12) :1334-1340
[14]   A parallel-detection frequency-domain near-infrared tomography system for hemoglobin imaging of the breast in vivo [J].
McBride, TO ;
Pogue, BW ;
Jiang, S ;
Osterberg, UL ;
Paulsen, KD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (03) :1817-1824
[15]   Time-correlated single photon counting imager for simultaneous magnetic resonance and near-infrared mammography [J].
Ntziachristos, V ;
Ma, XH ;
Chance, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (12) :4221-4233
[16]   Contrast-detail analysis for detection and characterization with near-infrared diffuse tomography [J].
Pogue, BW ;
Willscher, C ;
McBride, TO ;
Österberg, UL ;
Paulsen, KD .
MEDICAL PHYSICS, 2000, 27 (12) :2693-2700
[17]   Monte Carlo procedure for investigating light propagation and imaging of highly scattering media [J].
Sassaroli, A ;
Blumetti, C ;
Martelli, F ;
Alianelli, L ;
Contini, D ;
Ismaelli, A ;
Zaccanti, G .
APPLIED OPTICS, 1998, 37 (31) :7392-7400
[18]   A 32-channel time-resolved instrument for medical optical tomography [J].
Schmidt, FEW ;
Fry, ME ;
Hillman, EMC ;
Hebden, JC ;
Delpy, DT .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (01) :256-265
[19]   Multiple-slice imaging of a tissue-equivalent phantom by use of time-resolved optical tomography [J].
Schmidt, FEW ;
Hebden, JC ;
Hillman, EMC ;
Fry, ME ;
Schweiger, M ;
Dehghani, H ;
Delpy, DT ;
Arridge, SR .
APPLIED OPTICS, 2000, 39 (19) :3380-3387
[20]   Instrumentation for fast functional optical tomography [J].
Schmitz, CH ;
Löcker, M ;
Lasker, JM ;
Hielscher, AH ;
Barbour, RL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02) :429-439