In vivo high-contrast imaging of deep posterior eye by 1-μm swept source optical coherence tomography and scattering optical coherence angiography

被引:282
作者
Yasuno, Yoshiaki [1 ]
Hong, Youngjoo
Makita, Shuichi
Yamanari, Masahiro
Akiba, Masahiro
Miura, Masahiro
Yatagai, Toyohiko
机构
[1] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 305, Japan
[2] Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki, Japan
[3] Yamagata Promot Org Ind Technol, Yamagata, Japan
[4] Tokyo Med Univ, Dept Ophthalmol, Tokyo, Japan
[5] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 305, Japan
关键词
D O I
10.1364/OE.15.006121
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Retinal, choroidal and scleral imaging by using swept-source optical coherence tomography (SS-OCT) with a 1-mu m band probe light, and high-contrast and three-dimensional (3D) imaging of the choroidal vasculature are presented. This SS-OCT has a measurement speed of 28,000 A-lines/s, a depth resolution of 10.4 mu m in tissue, and a sensitivity of 99.3 dB. Owing to the high penetration of the 1-mu m probe light and the high sensitivity of the system, the in vivo sclera of a healthy volunteer can be observed. A software-based algorithm of scattering optical coherence angiography (S-OCA) is developed for the high-contrast and 3D imaging of the choroidal vessels. The S-OCA is used to visualize the 3D choroidal vasculature of the in vivo human macula and the optic nerve head. Comparisons of S-OCA with several other angiography techniques including Doppler OCA, Doppler OCT, fluorescein angiography, and indocyanine green angiography are also presented. (C) 2007 Optical Society of America.
引用
收藏
页码:6121 / 6139
页数:19
相关论文
共 68 条
[21]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[22]   Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography [J].
Huber, R ;
Wojtkowski, M ;
Fujimoto, JG .
OPTICS EXPRESS, 2006, 14 (08) :3225-3237
[23]   Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s [J].
Huber, Robert ;
Adler, Desmond C. ;
Fujimoto, James G. .
OPTICS LETTERS, 2006, 31 (20) :2975-2977
[24]   Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography [J].
Jiao, SL ;
Knighton, R ;
Huang, XR ;
Gregori, G ;
Puliafito, CA .
OPTICS EXPRESS, 2005, 13 (02) :444-452
[25]   In vivo optical frequency domain imaging of human retina and choroid [J].
Lee, Edward C. W. ;
de Boer, Johannes F. ;
Mujat, Mircea ;
Lim, Hyungsik ;
Yun, Seok H. .
OPTICS EXPRESS, 2006, 14 (10) :4403-4411
[26]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[27]   Ultrahigh resolution Fourier domain optical coherence tomography [J].
Leitgeb, RA ;
Drexler, W ;
Unterhuber, A ;
Hermann, B ;
Bajraszewski, T ;
Le, T ;
Stingl, A ;
Fercher, AF .
OPTICS EXPRESS, 2004, 12 (10) :2156-2165
[28]   Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography [J].
Leitgeb, RA ;
Schmetterer, L ;
Drexler, W ;
Fercher, AF ;
Zawadzki, RJ ;
Bajraszewski, T .
OPTICS EXPRESS, 2003, 11 (23) :3116-3121
[29]   High-speed imaging of human retina in vivo with swept-source optical coherence tomography [J].
Lim, H. ;
Mujat, M. ;
Kerbage, C. ;
Lee, E. C. W. ;
Chen, Y. ;
Chen, Teresa C. ;
de Boer, J. F. .
OPTICS EXPRESS, 2006, 14 (26) :12902-12908
[30]   Optical frequency domain imaging with a rapidly swept laser in the 815-870 nm range [J].
Lim, H. ;
de Boer, J. F. ;
Park, B. H. ;
Lee, E. C. W. ;
Yelin, R. ;
Yun, S. H. .
OPTICS EXPRESS, 2006, 14 (13) :5937-5944