Flow injection differential potentiometric determination of lysine by using a lysine biosensor

被引:28
作者
García-Villar, N [1 ]
Saurina, J [1 ]
Hernández-Cassou, S [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
differential potentiometry; lysine biosensor; ammonium electrode; flow injection analysis; lysine analysis; stopped-flow; partial least squares regression;
D O I
10.1016/S0003-2670(02)01426-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a method for the determination of lysine based on a flow injection (FI) differential potentiometry system. The flow injection manifold is composed of a support electrolyte solution channel and a water channel acting as a carrier into which the sample solution is injected. The lysine biosensor was consisted of lysine oxidase chemically immobilized on a nylon membrane and attached to an all-solid-state ammonium electrode. A circular ammonium electrode was used as a reference. Hence, the possible interference of endogenous ammonium can be partly corrected by differential potentiometry. In order to increase the sensitivity of the response, the reaction was kinetically developed following a stopped-flow method. As a result, the sensitivity increased from 20 to 40 mV per decade when comparing the FI and the stopped-flow values. Furthermore, the peak-to-peak stopped-flow signals generated can be used as a more selective analytical response for lysine. The quantification of lysine in mixture samples containing small amounts of ammonium can be achieved with an acceptable accuracy, with prediction errors lower than 4%. However, when the ammonium concentration exceeded the lysine concentration, multivariate calibration with non-linear partial least squares (PLS) regression was needed to improve the lysine quantification, with an overall prediction error around 10%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 29 条
[11]   Computational neural networks for the evaluation of biosensor FIA measurements [J].
Hitzmann, B ;
Ritzka, A ;
Ulber, R ;
Scheper, T ;
Schugerl, K .
ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) :135-141
[12]   Automated analytical biosystem for urea monitoring [J].
Jurkiewicz, M ;
delValle, M ;
Alegret, S ;
MartinezFabregas, E .
ANALYTICA CHIMICA ACTA, 1996, 327 (03) :243-251
[13]   Potentiometric determination of dialysate urea nitrogen [J].
Koncki, R ;
Radomska, A ;
Glab, S .
TALANTA, 2000, 52 (01) :13-17
[14]   Bioanalytical flow-injection system for control of hemodialysis adequacy [J].
Koncki, R ;
Radomska, A ;
Glab, S .
ANALYTICA CHIMICA ACTA, 2000, 418 (02) :213-224
[15]   Flow-injection analysis of Kjeldahl nitrogen in milk and dairy products by potentiometric detection [J].
Lima, JFCC ;
Delerue-Matos, C ;
Vaz, MC .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :437-441
[16]   Determination of total nitrogen in food by flow injection analysis (FIA) with a potentiometric differential detection system [J].
Lima, JLFC ;
Montenegro, MCBSM ;
Pinto, APMMO .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (04) :353-357
[17]   Cefuroxime selective electrodes for batch and FIA determinations in pharmaceutical preparations [J].
Lima, JLFC ;
Montenegro, MCBSM ;
Sales, MGF .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (1-2) :93-103
[18]   Selective flow injection procedures for the determination of nitrogen containing analytes by gasdialytic-fluorimetric detection of enzymatically generated ammonia [J].
Mana, H ;
Spohn, U .
ANALYTICA CHIMICA ACTA, 1996, 325 (1-2) :93-104
[19]   A flow injection system based on chalcogenide glass sensors for the determination of heavy metals [J].
Mortensen, J ;
Legin, A ;
Ipatov, A ;
Rudnitskaya, A ;
Vlasov, Y ;
Hjuler, K .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :273-277
[20]   ENZYMATIC DETERMINATION OF L-LYSINE BY FLOW-INJECTION TECHNIQUES [J].
POHLMANN, A ;
STAMM, WW ;
KUSAKABE, H ;
KULA, MR .
ANALYTICA CHIMICA ACTA, 1990, 235 (02) :329-335