Cell-compatible array of three-dimensional tip electrodes for the detection of nitric oxide release

被引:29
作者
Isik, S
Berdondini, L
Oni, J
Blöchl, A
Koudelka-Hep, M
Schuhmann, W
机构
[1] Ruhr Univ Bochum, Lehrstuhl Mol Neurobiochem, D-44780 Bochum, Germany
[2] Univ Neuchatel, Inst Microtechnol, CH-2000 Neuchatel, Switzerland
关键词
nitric oxides; array of electrodes; microfabrication; modified electrodes; endothelial cells;
D O I
10.1016/j.bios.2004.08.022
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An array of electrodes on which cells could be grown directly was fabricated using silicon anisotropic etching and a thick-photoresist process and employed for the detection of nitric oxide (NO) released from a population of adherently growing human umbilical vein endothelial cells (HUVEC). The electrodes are tip-shaped and are 40 mum high of which only the top 15 mum are exposed Pt-tips. After electrochemical induced modification of the exposed Pt tips using Ni phthalocyanine the individual addressable electrode tips were sensitive and selective for the detection of NO at an applied constant potential of 750 mV. The silicon nitride insulation of the lower part of the tip electrodes prevented the death of the cells upon the application of the working potential at which NO was detected. It also helped to avoid the perturbation of the integrity of the sensing chemistry imparted on the electrode surface that could have resulted from the contact of the adherently growing cells with the active electrode surface. The release of nitric oxide from HUVEC was Successfully monitored with different numbers of tip electrodes simultaneously connected as combined working electrode. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1566 / 1572
页数:7
相关论文
共 22 条
[11]   NITRIC-OXIDE RELEASE FROM A SINGLE CELL MEASURED INSITU BY A PORPHYRINIC-BASED MICROSENSOR [J].
MALINSKI, T ;
TAHA, Z .
NATURE, 1992, 358 (6388) :676-678
[12]   Electrochemical monitoring of biogenic amine neurotransmission in real time [J].
Michael, DJ ;
Wightman, RM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :33-46
[13]   Functionalised electrode array for the detection of nitric oxide released by endothelial cells using different NO-sensing chemistries [J].
Oni, J ;
Pailleret, A ;
Isik, S ;
Diab, N ;
Radtke, I ;
Blöchl, A ;
Jackson, M ;
Bedioui, F ;
Schuhmann, W .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (06) :1594-1600
[14]   Detection of NO release from endothelial cells using Pt micro electrodes modified with a pyrrole-functionalised Mn(II) porphyrin [J].
Oni, J ;
Diab, N ;
Radtke, I ;
Schuhmann, W .
ELECTROCHIMICA ACTA, 2003, 48 (20-22) :3349-3354
[15]   In situ formation and scanning electrochemical microscopy assisted positioning of NO-sensors above human umbilical vein endothelial cells for the detection of nitric oxide release [J].
Pailleret, A ;
Oni, J ;
Reiter, S ;
Isik, S ;
Etienne, M ;
Bedioui, F ;
Schuhmann, W .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (10) :847-852
[16]   Nickel tetrasulfonated phthalocyanine based platinum microelectrode array for nitric oxide oxidation [J].
Pereira-Rodrigues, N ;
Albin, V ;
Koudelka-Hep, M ;
Auger, V ;
Pailleret, A ;
Bedioui, F .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (11) :922-927
[17]   Direct electrochemical characterization of superoxide anion production and its reactivity toward nitric oxide in solution [J].
Privat, C ;
Trevin, S ;
Bedioui, F ;
Devynck, J .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 436 (1-2) :261-265
[18]   Determination of NO production in melanoma cells using an amperometric nitric oxide sensor [J].
Raveh, O ;
Peleg, N ;
Bettleheim, A ;
Silberman, I ;
Rishpon, J .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 43 (01) :19-25
[19]   Nitric oxide measurements in biological samples [J].
Taha, ZH .
TALANTA, 2003, 61 (01) :3-10
[20]   An array of Pt-tip microelectrodes for extracellular monitoring of activity of brain slices [J].
Thiébaud, P ;
Beuret, C ;
Koudelka-Hep, M ;
Bove, M ;
Martinoia, S ;
Grattarola, M ;
Jahnsen, H ;
Rebaudo, R ;
Balestrino, M ;
Zimmer, J ;
Dupont, Y .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (01) :61-65