dc and ac optical nulling bridges for sensitive transmittance measurements

被引:7
作者
Argueta-Díaz, V [1 ]
Trejo-Valdez, M [1 ]
García-Valenzuela, A [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Ctr Instrumentos, Lab Opt Aplicada, Mexico City 04510, DF, Mexico
关键词
D O I
10.1063/1.1305509
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a formal comparison between dc and ac nulling optical bridges. We consider their performance in monitoring over long periods of time (several minutes), small and slow (in a time scale of seconds) changes in transmittance of an optical component. We consider two fundamentally different ac optical bridges (OB), an amplitude modulated optical bridge (AM-OB), and a switching optical bridge (Sw-OB). For each OB, we derive a general expression for the minimum detectable change in transmittance (\Delta T\(min)), taking into account all the important noises. It is found that under optimum conditions the dc- and AM-OB have similar detection limits imposed by the 1/f noise of the photodetectors. It is shown that the Sw-OB can in principle overcome the 1/f noise of the detector and approach the shot-noise limit; however, it is sensitive to switching device imperfections (to first order in smallness), which could easily prevent achieving a detection limit below the 1/f noise. It is also shown that the Sw-OB has intrinsic advantages over the dc- and AM-OB for its use in remote sensors. It can eliminate more efficiently noise induced along the propagation of light from the sensing point to the photodetector. We conclude that when using low power optics (P less than or equal to 1 mW) and considering a bench instrument, the dc- and AM-OB can be used for a target resolution down to \Delta T\(min)approximate to 10(-5)-10(-6). The Sw-OB optical bridges should be chosen if \Delta T\(min)approximate to 10(-6)-10(-8) is to be attempted. In any case, strict conditions are to be met before considering approaching the detection limits imposed by electronic noises. These conditions are discussed in detail. In particular, atmospheric isolation will be needed in general below \Delta T\(min)approximate to 10(-4). (C) 2000 American Institute of Physics. [S0034-6748(00)03008-2].
引用
收藏
页码:2995 / 3003
页数:9
相关论文
共 19 条
[11]  
LIPPITSCH ME, 1997, APPL OPTICS, V35, P3426
[12]   TEST OF MIRROR PAIR REFLECTIVITY COEFFICIENT EQUALITY AND HOMOGENEITY FOR INTERFEROMETRIC GRAVITATIONAL-WAVE DETECTORS [J].
LORIETTE, V .
JOURNAL OF OPTICS-NOUVELLE REVUE D OPTIQUE, 1995, 26 (01) :35-38
[13]   High-sensitivity reflectometer at 1.064 μm for testing the homogeneity of the optical components of gravitational wave antennas [J].
Loriette, V ;
Nahoum, R .
JOURNAL OF OPTICS-NOUVELLE REVUE D OPTIQUE, 1998, 29 (04) :268-274
[14]   Analysis of the sensitivity of optical waveguide chemical sensors for TM modes by the group-index method [J].
Qing, DK ;
Yamaguchi, I .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1999, 16 (09) :1359-1369
[15]   Low noise position sensitive detector for optical probe beam deflection measurements [J].
Spear, JD ;
Russo, RE .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (07) :2481-2484
[16]   Ion- and substrate-selective optode membranes and optical detection modes [J].
SpichigerKeller, UE .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 38 (1-3) :68-77
[17]   A ppb-level NO2 gas sensor using coloration reactions in porous glass [J].
Tanaka, T ;
Guilleux, A ;
Ohyama, T ;
Maruo, YY ;
Hayashi, T .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (03) :247-253
[18]   SIMPLE HIGH-PRECISION METHOD FOR MEASURING THE SPECULAR REFLECTANCE OF OPTICAL-COMPONENTS [J].
VOSS, A ;
PLASS, W ;
GIESEN, A .
APPLIED OPTICS, 1994, 33 (36) :8370-8374
[19]  
WEBER MJ, 1986, CRC HDB LASER SCI, V4, P70