In vivo gated 4D imaging of the embryonic heart using optical coherence tomography

被引:74
作者
Jenkins, Michael W.
Chughtai, Osman Q.
Basavanhally, Ajay N.
Watanabe, Michiko
Rollins, Andrew M.
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Sch Med, Dept Pediat, Cleveland, OH 44106 USA
关键词
optical coherence tomography; embryonic hearts; medical imaging; avian embryos; gated imaging;
D O I
10.1117/1.2747208
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We demonstrate the first in vivo gated 4D images of avian embryonic hearts by use of optical coherence tomography (OCT). We present a gated 4D dataset of an in vivo beating quail heart consisting of similar to 864,000 A-scans accumulated over multiple heartbeats. Generation of a gating trigger from a laser Doppler velocimetry (LDV) signal, collected from an outlying vitelline vessel, enabled us to gate image acquisition to the cardiac cycle. To fully characterize the genesis and mechanisms of cardiac defects, a tool capable of assessing structure and function simultaneously at early stages of development is needed, and gated OCT has the capability to become such a tool. (C) 2007 society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:3
相关论文
共 12 条
[1]   Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography [J].
Boppart, SA ;
Tearney, GJ ;
Bouma, BE ;
Southern, JF ;
Brezinski, ME ;
Fujimoto, JG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (09) :4256-4261
[2]  
DAVIS AM, 2002, P SOC PHOTO-OPT INS, V6429, pR4290
[3]   Quasi-telecentric optical design of a microscope-compatible OCT scanner [J].
Hu, ZL ;
Rollins, AM .
OPTICS EXPRESS, 2005, 13 (17) :6407-6415
[4]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[5]   Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s [J].
Huber, Robert ;
Adler, Desmond C. ;
Fujimoto, James G. .
OPTICS LETTERS, 2006, 31 (20) :2975-2977
[6]   Phenotyping transgenic embryonic murine hearts using optical coherence tomography [J].
Jenkins, Michael W. ;
Patel, Pankti ;
Deng, Huayun ;
Montano, Monica M. ;
Watanabe, Michiko ;
Rollins, Andrew M. .
APPLIED OPTICS, 2007, 46 (10) :1776-1781
[7]   4D embryonic cardiography using gated optical coherence tomography [J].
Jenkins, MW ;
Rothenberg, F ;
Roy, D ;
Nikolski, VP ;
Hu, Z ;
Watanabe, M ;
Wilson, DL ;
Efimov, IR ;
Rollins, AM .
OPTICS EXPRESS, 2006, 14 (02) :736-748
[8]   Four-dimensional cardiac imaging in living embryos via postacquisition synchronization of nongated slice sequences [J].
Liebling, M ;
Forouhar, AS ;
Gharib, M ;
Fraser, SE ;
Dickinson, ME .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (05)
[9]   Three-dimensional optical coherence tomography of the embryonic murine cardiovascular system [J].
Luo, Wei ;
Marks, Daniel L. ;
Ralston, Tyler S. ;
Boppart, Stephen A. .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (02)
[10]   In vivo video rate optical coherence tomography [J].
Rollins, AM ;
Kulkarni, MD ;
Yazdanfar, S ;
Ung-arunyawee, R ;
Izatt, JA .
OPTICS EXPRESS, 1998, 3 (06) :219-229