Microfluidics/microfabrication; Immunoassays/ELISA; Biosensors; Bioanalytical methods; Fluid handling/automation multiplex analysis; LINKED-IMMUNOSORBENT-ASSAY; C-REACTIVE PROTEIN; ON-A-CHIP; SIMULTANEOUS MULTIPLE IMMUNOASSAYS; ASSISTED DENDRITIC AMPLIFICATION; LATEX IMMUNOAGGLUTINATION ASSAY; BEAD-BASED IMMUNOASSAY; HUMAN SERUM; LABEL-FREE; CAPILLARY-ELECTROPHORESIS;
D O I
10.1007/s00216-010-3678-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Immunoassays have greatly benefited from miniaturization in microfluidic systems. This review, which summarizes developments in microfluidics-based immunoassays since 2000, includes four sections, focusing on the configurations of immunoassays that have been implemented in microfluidics, the main fluid handling modalities that have been used for microfluidic immunoassays, multiplexed immunoassays in microfluidic platforms, and the emergence of label-free detection techniques. The field of microfluidic immunoassays is continuously improving and has great promise for the future.
引用
收藏
页码:991 / 1007
页数:17
相关论文
共 187 条
[131]   An array immunosensor for simultaneous detection of clinical analytes [J].
Rowe, CA ;
Scruggs, SB ;
Feldstein, MJ ;
Golden, JP ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :433-439
[132]   Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection [J].
Sato, K ;
Yamanaka, M ;
Hagino, T ;
Tokeshi, M ;
Kimura, H ;
Kitamori, T .
LAB ON A CHIP, 2004, 4 (06) :570-575
[133]   Integration of an immunoassay system into a microchip for high-throughput assay [J].
Sato, K ;
Kitamori, T .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2004, 4 (06) :575-579
[134]  
Sato K, 2002, ELECTROPHORESIS, V23, P734, DOI 10.1002/1522-2683(200203)23:5<734::AID-ELPS734>3.0.CO
[135]  
2-W
[136]   Determination of carcinoembryonic antigen in human sera by integrated bead bed immunoasay in a microchip for cancer diagnosis [J].
Sato, K ;
Tokeshi, M ;
Kimura, H ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1213-1218
[137]   Integration of an immunosorbent assay system: Analysis of secretory human immunoglobulin A on polystyrene beads in a microchip [J].
Sato, K ;
Tokeshi, M ;
Odake, T ;
Kimura, H ;
Ooi, T ;
Nakao, M ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1144-1147
[138]   User Configurable Microfluidic Device for Multiplexed Immunoassays Based on DNA-Directed Assembly [J].
Schroeder, Hendrik ;
Adler, Michael ;
Gerigk, Katrin ;
Mueller-Chorus, Birgit ;
Goetz, Friedrich ;
Niemeyer, Christof M. .
ANALYTICAL CHEMISTRY, 2009, 81 (03) :1275-1279
[139]   Detection of antigens in biologically complex fluids with photografted whole antibodies [J].
Sebra, Robert P. ;
Masters, Kristyn S. ;
Cheung, Charles Y. ;
Bowman, Christopher N. ;
Anseth, Kristi S. .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :3144-3151
[140]   Gradient elution moving boundary electrophoresis for high-throughput multiplexed microfluidic devices [J].
Shackman, Jonathan G. ;
Munson, Matthew S. ;
Ross, David .
ANALYTICAL CHEMISTRY, 2007, 79 (02) :565-571