NUCLEAR-REACTION ANALYSIS OF DEUTERIUM IN DEUTERIDED ZR-2.5 WT-PERCENT NB ALLOY

被引:20
作者
LAURSEN, T
KOELBL, RS
机构
[1] Queen's Univ, Physics Dep, Kingston,, Ont, Can, Queen's Univ, Physics Dep, Kingston, Ont, Can
关键词
DEUTERIUM - NUCLEAR REACTORS; HEAVY WATER - Piping Systems;
D O I
10.1016/0022-3115(86)90226-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The deuterium concentration of homogeneous bulk levels in Zr-2. 5 wt% Nb alloy has been measured by nuclear reaction analysis. The accuracy is plus or minus 10% which is comparable to the accuracy of gas analytical techniques. A large surface peak is seen in all the samples due to a deuteride rich layer less than 20 nm thick. The deuterium concentration in this surface layer is more than 10 times the bulk value. At high ion beam fluences, significant effects due to the analyzing beam are seen in the deuterium depth distribution. These are ascribed to deuterium trapping in the **3He implanted region, deuterium diffusion and dissolution of deuterides. These samples are not recommended as general deuterium standards for ion beam analysis experiments because of ion beam effects and the presence of a surface peak. However, they still serve as a useful reference when care is taken to avoid effects due to high fluences.
引用
收藏
页码:241 / 249
页数:9
相关论文
共 27 条
[11]  
ESKILDSEN SS, 1982, ION IMPLANTATION MET
[12]   DEFECT TRAPPING OF HYDROGEN IN IRON STUDIED BY THE H-1(N-15, ALPHA-GAMMA)C-12 REACTION [J].
FRECH, G ;
WOLF, GK ;
DAMJANTSCHITSCH, H ;
WEISER, M ;
KALBITZER, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 218 (1-3) :500-503
[13]   DEPTH DISTRIBUTION PROFILING OF DEUTERIUM AND HE-3 [J].
LANGLEY, RA ;
PICRAUX, ST ;
VOOK, FL .
JOURNAL OF NUCLEAR MATERIALS, 1974, 53 (01) :257-261
[14]  
LEGER M, 1980, 80233K ONT HYDR RES
[15]   NOTE ON THE HE-3+D NUCLEAR-REACTION CROSS-SECTION [J].
MOLLER, W ;
BESENBACHER, F .
NUCLEAR INSTRUMENTS & METHODS, 1980, 168 (1-3) :111-114
[16]   BACKGROUND REDUCTION IN D(HE-3-ALPHA)H DEPTH PROFILING EXPERIMENTS USING A SIMPLE ELECTROSTATIC DEFLECTOR [J].
MOLLER, W .
NUCLEAR INSTRUMENTS & METHODS, 1978, 157 (02) :223-227
[17]   THE BEHAVIOR OF HYDROGEN-ATOMS IMPLANTED INTO METALS [J].
MOLLER, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 209 (MAY) :773-790
[18]   DEFECT TRAPPING OF ION-IMPLANTED DEUTERIUM IN FE [J].
MYERS, SM ;
PICRAUX, ST ;
STOLTZ, RE .
JOURNAL OF APPLIED PHYSICS, 1979, 50 (09) :5710-5719
[19]   ION-BEAM-INDUCED MIGRATION AND ITS EFFECT ON CONCENTRATION PROFILES [J].
MYERS, SM .
NUCLEAR INSTRUMENTS & METHODS, 1980, 168 (1-3) :265-274
[20]   TRAPPING AND SURFACE RECOMBINATION OF ION-IMPLANTED DEUTERIUM IN STAINLESS-STEEL [J].
MYERS, SM ;
WAMPLER, WR ;
BESENBACHER, F .
JOURNAL OF APPLIED PHYSICS, 1984, 56 (06) :1561-1571