The cumulative verification image analysis tool for offline evaluation of portal images

被引:16
作者
Wong, J [1 ]
Yan, D [1 ]
Michalski, J [1 ]
Graham, M [1 ]
Halverson, K [1 ]
Harms, W [1 ]
Purdy, J [1 ]
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,DIV RADIAT ONCOL,ST LOUIS,MO 63110
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 33卷 / 05期
关键词
portal imaging; treatment verification; daily setup variation; setup error analysis;
D O I
10.1016/0360-3016(95)00270-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Daily portal images acquired using electronic portal imaging devices contain important information about the setup variation of the individual patient, The data can be used to evaluate the treatment and to derive correction for the individual patient. The large volume of images also require software tools for efficient analysis, This article describes the approach of cumulative verification image analysis (CVIA) specifically designed as an offline tool to extract quantitative information from daily portal images. Methods and Materials: The user interface, image and graphics display, and algorithms of the CVIA tool have been implemented in ANSCI C using the X Window graphics standards. The tool consists of three major components: (a) definition of treatment geometry and anatomical information; (b) registration of portal images with a reference image to determine setup variation; and (c) quantitative analysis of all setup variation measurements, The CVIA tool is not automated, User interaction is required and preferred, Successful alignment of anatomies on portal images at present remains mostly dependent on clinical judgment, Predefined templates of block shapes and anatomies are used for image registration to enhance efficiency, taking advantage of the fact that much of the tool's operation is repeated in the analysis of daily portal images. Results: The CVIA tool is portable and has been implemented on workstations with different operating systems, Analysis of 20 sequential daily portal images can be completed in less than 1 h, The temporal information is used to characterize setup variation in terms of its systematic, random and time-dependent components, The cumulative information is used to derive block overlap isofrequency distributions (BOIDs), which quantify the effective coverage of the prescribed treatment area throughout the course of treatment, Finally, a set of software utilities is available to facilitate feedback of the information for treatment plan recalculation and to test various decision strategies for treatment adjustment. Conclusions: The CVIA tool provides comprehensive analysis of daily images acquired with electronic portal imaging devices, Its offline approach allows characterization of the nature of setup variation for the individual patient that would have been difficult to deduce using only a few daily or weekly portal images, Distribution of the tool will help establish an important database of setup variation from many clinics, The information derived from CVIA can also serve as the foundation to integrate treatment verification, treatment planning, and treatment delivery.
引用
收藏
页码:1301 / 1310
页数:10
相关论文
共 46 条
[1]   MEASUREMENT OF PROSTATE MOTION OVER THE COURSE OF RADIOTHERAPY [J].
BALTER, J ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 :223-223
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[4]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[5]   RADIATION-FIELD EDGE-DETECTION IN PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M ;
MEERTENS, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1705-1710
[6]   FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES [J].
BIJHOLD, J ;
VANHERK, M ;
VIJLBRIEF, R ;
LEBESQUE, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1665-1679
[7]  
BOYER A, 1992, MED PHYS, V19, P802
[8]   A NOVEL ALGORITHM FOR THE EDGE-DETECTION AND EDGE ENHANCEMENT OF MEDICAL IMAGES [J].
CROOKS, I ;
FALLONE, BG .
MEDICAL PHYSICS, 1993, 20 (04) :993-998
[9]   ROUTINE CLINICAL ONLINE PORTAL IMAGING FOLLOWED BY IMMEDIATE FIELD ADJUSTMENT USING A TELE-CONTROLLED PATIENT COUCH [J].
DENEVE, W ;
VANDENHEUVEL, F ;
DEBEUKELEER, M ;
COGHE, M ;
THON, L ;
DEROOVER, P ;
VANLANCKER, M ;
STORME, G .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (01) :45-54
[10]   OBJECTIVE DECISION-MAKING FOLLOWING A PORTAL FILM - THE RESULTS OF A PILOT-STUDY [J].
DENHAM, JW ;
DALLY, MJ ;
HUNTER, K ;
WHEAT, J ;
FAHEY, PP ;
HAMILTON, CS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (05) :869-876