Newer-generation ventricular assist devices

被引:34
作者
Agarwal, Shvetank [1 ]
High, Kane M. [1 ]
机构
[1] Penn State Hershey, Dept Anesthesiol, POB 850, Hershey, PA 17033 USA
关键词
ventricular assist pump; centrifugal blood pump; axial blood pump; cardiac failure;
D O I
10.1016/j.bpa.2012.01.003
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The latest generation of ventricular assist devices has evolved from the pulsatile, volume-displacement pumps of the 1990s to today's non-pulsatile, constant pressure-generating rotary pumps. These pumps include both centrifugal and axial flow devices that are currently being used or are in advanced development. Rotary pumps have the advantage of a much longer and more reliable duty life than pulsatile pumps. They are also considerably smaller than pulsatile pumps, requiring less invasive surgery for implantation and smaller transcutaneous (electrical rather than pneumatic) drivelines. Most of these devices have been approved as a bridge to transplant (BTT) while some are currently in trials for destination therapy (DT) in Europe (Conformite Europeenne (CE) mark) or the United States (Food and Drug Administration (FDA)). This article discusses the current generation of pumps, examining particular design features as highlighted by the designers as well as the current approval status of each device in the United States and Europe. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:117 / 130
页数:14
相关论文
共 52 条
[1]   A novel counterpulsation mode of rotary left ventricular assist devices can enhance myocardial perfusion [J].
Ando, Masahiko ;
Takewa, Yoshiaki ;
Nishimura, Takashi ;
Yamazaki, Kenji ;
Kyo, Shunei ;
Ono, Minoru ;
Tsukiya, Tomonori ;
Mizuno, Toshihide ;
Taenaka, Yoshiyuki ;
Tatsumi, Eisuke .
JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (03) :185-191
[2]   A novel counterpulse drive mode of continuous-flow left ventricular assist devices can minimize intracircuit backward flow during pump weaning [J].
Ando, Masahiko ;
Nishimura, Takashi ;
Takewa, Yoshiaki ;
Ogawa, Daisuke ;
Yamazaki, Kenji ;
Kashiwa, Koichi ;
Kyo, Shunei ;
Ono, Minoru ;
Taenaka, Yoshiyuki ;
Tatsumi, Eisuke .
JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (01) :74-79
[3]   Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices [J].
Crow, Sheri ;
John, Ranjit ;
Boyle, Andrew ;
Shumway, Sara ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Toninato, Carol ;
Missov, Emil ;
Pritzker, Marc ;
Martin, Cindy ;
Garry, Daniel ;
Thomas, William ;
Joyce, Lyle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :208-215
[4]  
Dang NC, 2006, J HEART LUNG TRANSPL, V25, P1, DOI 10.1016/j.healun.2005.07.008
[5]   A miniature implantable axial flow ventricular assist device [J].
DeBakey, ME .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :637-640
[6]   Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: Third Annual Report - 2005 [J].
Deng, MC ;
Edwards, LB ;
Hertz, MI ;
Rowe, AW ;
Keck, BM ;
Kormos, R ;
Naftel, DC ;
Kirklin, JK ;
Taylor, DO .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (09) :1182-1187
[7]   Design features, developmental status, and experimental results with the heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor [J].
Farrar, David J. ;
Bourque, Kevin ;
Dague, Charles P. ;
Cotter, Christopher J. ;
Poirier, Victor L. .
ASAIO JOURNAL, 2007, 53 (03) :310-315
[8]   Optimization of axial-pump pressure sensitivity for a continuous-flow total artificial heart [J].
Frazier, O. H. ;
Khalil, Hassan A. ;
Benkowski, Robert J. ;
Cohn, William E. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (06) :687-691
[9]   Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: A feasibility study [J].
Frazier, OH ;
Tuzun, E ;
Cohn, WE ;
Conger, JL ;
Kadipasaoglu, KA .
ASAIO JOURNAL, 2006, 52 (02) :145-149
[10]   Use of the Flowmaker (Jarvik 2000) left ventricular assist device for destination therapy and bridging to transplantation [J].
Frazier, OH ;
Shah, NA ;
Myers, TJ ;
Robertson, KD ;
Gregoric, ID ;
Delgado, R .
CARDIOLOGY, 2004, 101 (1-3) :111-116