Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT

被引:37
作者
Behrendt, Florian F. [1 ]
Pietsch, Hubertus [2 ]
Jost, Gregor [2 ]
Sieber, Martin A. [2 ]
Keil, Sebastian [1 ]
Plumhans, Cedric [1 ]
Seidensticker, Peter [2 ]
Guenther, Rolf W. [1 ]
Mahnken, Andreas H. [1 ,3 ]
机构
[1] Rhein Westfal TH Aachen, Univ Hosp, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Bayer Schering Pharma AG, Berlin, Germany
[3] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Aachen, Germany
关键词
Contrast media; Computed tomography; Intraindividual comparison; Iodine concentration; Administration and dosage; Reproducibility of results; HEPATIC ENHANCEMENT; COMPUTED-TOMOGRAPHY; INJECTION PROTOCOL; PEAK ENHANCEMENT; PATIENT WEIGHT; PORCINE MODEL; CHEST CT; ANGIOGRAPHY; PRINCIPLES; RATIONALE;
D O I
10.1007/s00330-010-1717-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To compare intra-individual contrast enhancement in multi-detector-row computed tomography (MDCT) using contrast media (CM) containing 300, 370 and 400 mg iodine per ml (mgI/ml). Six pigs underwent repeated chest MDCT using three different CM (iopromide 300, iopromide 370, iomeprol 400). An identical iodine delivery (IDR) rate of 1.5 gI/s and a constant total iodine dose of 300 mg/kg body weight were used. Dynamic CT were acquired at the level of the pulmonary artery, and the ascending and descending aorta. After the time enhancement curves were computed, the pulmonary and aortic peak enhancement, time to peak and plateau time above 300 HU were calculated. Intra-individual peak contrast enhancement was significantly higher for the 300 mgI/ml contrast medium compared with the 370 and 400 mgI/ml media: pulmonary trunk 595 HU vs 516 HU (p = 0.0093) vs 472HU (p = 0.0005), and aorta 505 HU vs 454 HU (p = 0.0008) vs 439 HU (p = 0.0001), respectively. Comparison of time to peaks showed no significant difference. Plateau times were significantly longer for the 300 mgI/ml than for the 370 and 400 mgI/ml CM at all anatomical sites. Given normalised IDR and total iodine burden, the use of CM with a standard concentration with 300 mg iodine/ml provides improved contrast enhancement compared with highly concentrated CM in the chest.
引用
收藏
页码:1644 / 1650
页数:7
相关论文
共 19 条
[1]
Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[2]
Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[3]
Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :647-655
[4]
Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[5]
Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise [J].
Benner, T ;
Heiland, S ;
Erb, G ;
Forsting, M ;
Sartor, K .
MAGNETIC RESONANCE IMAGING, 1997, 15 (03) :307-317
[6]
Use of high concentration contrast media (HCCM): principles and rationale - body CT [J].
Brink, JA .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 :S53-S58
[7]
HEPATIC SPIRAL CT - REDUCTION OF DOSE OF INTRAVENOUS CONTRAST MATERIAL [J].
BRINK, JA ;
HEIKEN, JP ;
FORMAN, HP ;
SAGEL, SS ;
MOLINA, PL ;
BROWN, PC .
RADIOLOGY, 1995, 197 (01) :83-88
[8]
High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400 [J].
Cademartiri, F ;
de Monye, C ;
Pugliese, F ;
Mollet, NR ;
Runza, G ;
van der Lugt, A ;
Midiri, M ;
de Feyter, PJ ;
Lagalla, R ;
Krestin, GP .
INVESTIGATIVE RADIOLOGY, 2006, 41 (03) :349-353
[9]
HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM ;
DODD, GD ;
MILLER, WJ ;
CONFER, SR .
RADIOLOGY, 1993, 188 (03) :627-631