A decade of microfluidic analysis coupled with electrospray mass spectrometry: An overview

被引:147
作者
Koster, Sander [1 ]
Verpoorte, Elisabeth [1 ]
机构
[1] Univ Groningen, Groningen Res Inst Pharm, NL-9713 AV Groningen, Netherlands
关键词
D O I
10.1039/b709706a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This review presents a thorough overview covering the period 1997-2006 of microfluidic chips coupled to mass spectrometry through an electrospray interface. The different types of fabrication processes and materials used to fabricate these chips throughout this period are discussed. Three 'eras' of interfaces are clearly distinguished. The earliest approach involves spraying from the edge of a chip, while later devices either incorporate a standard fused-silica emitter inserted into the device or fully integrated emitters formed during chip fabrication. A summary of microfluidic-electrospray devices for performing separations and sample pretreatment steps before sample introduction into the mass spectrometer is also presented.
引用
收藏
页码:1394 / 1412
页数:19
相关论文
共 198 条
[1]  
Abian J, 1999, J MASS SPECTROM, V34, P244, DOI 10.1002/(SICI)1096-9888(199904)34:4<244::AID-JMS775>3.0.CO
[2]  
2-0
[3]   Nanoelectrospray ion generation for high-throughput mass spectrometry using a micromachined ultrasonic ejector array [J].
Aderogba, S ;
Meacham, JM ;
Degertekin, FL ;
Fedorov, AG ;
Fernandez, FM .
APPLIED PHYSICS LETTERS, 2005, 86 (20) :1-3
[4]   Top-down analysis of basic proteins by microchip capillary electrophoresis mass spectrometry [J].
Akashi, Satoko ;
Suzuki, Koichi ;
Arai, Akihiro ;
Yamada, Naoyuki ;
Suzuki, Ei-Ichiro ;
Hirayama, Kazuo ;
Nakamura, Shin ;
Nishimura, Yoshifumi .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (12) :1932-1938
[5]   MICRO-ELECTROSPRAY - ZEPTOMOLE-ATTOMOLE PER MICROLITER SENSITIVITY FOR PEPTIDES [J].
ANDREN, PE ;
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (09) :867-869
[6]   A polysilicon nanoelectrospray-mass spectrometry source based on a microfluidic capillary slot [J].
Arscott, S ;
Le Gac, S ;
Rolando, C .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (02) :741-749
[7]   A micro-nib nanoelectro spray source for mass spectrometry [J].
Arscott, S ;
Le Gac, S ;
Druon, C ;
Tabourier, P ;
Rolando, C .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 98 (2-3) :140-147
[8]   A planar on-chip micro-nib interface for NanoESI-MS microfluidic applications [J].
Arscott, S ;
Le Gac, S ;
Druon, C ;
Tabourier, P ;
Rolando, C .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (02) :310-316
[9]   Micromachined 2D nanoelectrospray emitter [J].
Arscott, S ;
Le Gac, S ;
Druon, C ;
Tabourier, P ;
Rolando, C .
ELECTRONICS LETTERS, 2003, 39 (24) :1702-1703
[10]   Capillary filling of miniaturized sources for electrospray mass spectrometry [J].
Arscott, Steve ;
Gaudet, Matthieu ;
Brinkmann, Martin ;
Ashcroft, Alison E. ;
Blossey, Ralf .
JOURNAL OF PHYSICS-CONDENSED MATTER, 2006, 18 (18) :S677-S690