New analytical portable instrument for microchip electrophoresis with electrochemical detection

被引:20
作者
Fernandez-la-Villa, Ana [1 ]
Pozo-Ayuso, Diego F. [1 ]
Castano-Alvarez, Mario [1 ]
机构
[1] MicruX Fluid SL, Oviedo 33006, Asturias, Spain
关键词
Bipotentiostat; Chip holder; Electrochemical detection; High voltage power supply; Microchip electrophoresis; CONTACTLESS CONDUCTIVITY DETECTION; TOTAL ANALYSIS SYSTEMS; CAPILLARY-ELECTROPHORESIS; MICROFLUIDIC DEVICES; THERMOSET POLYESTER; FABRICATION; CHIP; CE; PERFORMANCE; DESIGN;
D O I
10.1002/elps.201000100
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new portable instrument that includes a high voltage power supply, a bipotentiostat, and a chip holder has been especially developed for using microchips electrophoresis with electrochemical detection. The main unit of the instrument has dimensions of 150 x 165 x 70 mm (w x d x h) and consists of a four-outputs high voltage power supply with a maximum voltage of +/- 3 KV and an acquisition system with two channels for dual amperometric (DC or pulsed amperometric detection) detection. Electrochemical detection has been selected as signal transduction method because it is relatively easily implemented, since nonoptical elements are required. The system uses a lithium-ion polymer battery and it is controlled from a desktop or laptop PC with a graphical user interface based on LabVIEW connected by serial RS232 or Bluetooth (R). The last part of the system consists of a reusable chip holder for housing the microchips, which contain all the electrical connections and reservoirs for making the work with microchips easy. The performance of the new instrument has been evaluated and compared with other commercially available apparatus using single- and dual-channel pyrex microchips for the separation of the neurotransmitters dopamine, epinephrine, and 3,4-dihydroxy-L-phenyl-alanine. The reduction of the size of the instrument has not affected the good performance of the separation and detection using microchips electrophoresis with electrochemical detection. Moreover, the new portable instrument paves the way for in situ analysis making the use of microchips electrophoresis easier.
引用
收藏
页码:2641 / 2649
页数:9
相关论文
共 61 条
[1]   Polyelectrolyte-modified short microchannel for cation separation [J].
Bai, XX ;
Roussel, C ;
Jensen, H ;
Girault, HH .
ELECTROPHORESIS, 2004, 25 (06) :931-935
[2]   An integrated CMOS high voltage supply for lab-on-a-chip systems [J].
Behnam, M. ;
Kaigala, G. V. ;
Khorasani, M. ;
Marshall, P. ;
Backhouse, C. J. ;
Elliott, D. G. .
LAB ON A CHIP, 2008, 8 (09) :1524-1529
[3]   Lab-on-a-robot: Integrated microchip CE, power supply, electrochemical detector, wireless unit, and mobile platform [J].
Berg, Christopher ;
Valdez, David C. ;
Bergeron, Phillip ;
Mora, Maria F. ;
Garcia, Carlos D. ;
Ayon, Arturo .
ELECTROPHORESIS, 2008, 29 (24) :4914-4921
[4]   Poly(methylmethacrylate) and Topas capillary electrophoresis microchip performance with electrochemical detection [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
ELECTROPHORESIS, 2005, 26 (16) :3160-3168
[5]   Critical points in the fabrication of microfluidic devices on glass substrates [J].
Castano-Alvarez, Mario ;
Pozo Ayuso, Diego F. ;
Garcia Granda, Miguel ;
Teresa Fernandez-Abedul, M. ;
Rodriguez Garcia, Jose ;
Costa-Garcia, Agustin .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (01) :436-448
[6]   Electroactive intercalators for DNA analysis on microchip electrophoresis [J].
Castano-Alvarez, Mario ;
Teresa Fernandez-Abedul, M. ;
Costa-Garcia, Agustin .
ELECTROPHORESIS, 2007, 28 (24) :4679-4689
[7]   Multiple-point electrochemical detection for a dual-channel hybrid PDMS-glass microchip electrophoresis device [J].
Castano-Alvarez, Mario ;
Fernandez-la-Vilia, Ana ;
Pozo-Ayuso, Diego F. ;
Teresa Fernandez-Abedul, Maria ;
Costa-Garcia, Agustin .
ELECTROPHORESIS, 2009, 30 (19) :3372-3380
[8]   Fabrication of SU-8 based microchip electrophoresis with integrated electrochemical detection for neurotransmitters [J].
Castano-Alvarez, Mario ;
Teresa Fernandez-Abedul, M. ;
Costa-Garcia, Agustin ;
Agirregabiria, Maria ;
Fernandez, Luis J. ;
Miguel Ruano-Lopez, Jesus ;
Barredo-Presa, Borja .
TALANTA, 2009, 80 (01) :24-30
[9]   MCE-electrochemical detection for following interactions of ssDNA and dsDNA with methylene blue [J].
Castano-Alvarez, Mario ;
Fernandez-la-Villa, Ana ;
Teresa Fernandez-Abedul, Maria ;
Costa-Garcia, Agustin .
ELECTROPHORESIS, 2009, 30 (11) :1943-1948
[10]   Fabrication, modification, and application of department of analytical poly(methyl methacrylate) microfluidic chips [J].
Chen, Yun ;
Zhang, Luyan ;
Chen, Gang .
ELECTROPHORESIS, 2008, 29 (09) :1801-1814