Novel planar glucose biosensors for continuous monitoring use

被引:56
作者
Ricci, F
Moscone, D
Tuta, CS
Palleschi, G
Amine, A
Poscia, A
Valgimigli, F
Messeri, D
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
[2] Fac Sci & Tech Mohammadia, Mohammadia, Morocco
关键词
glucose; continuous monitoring; screen-printed; mediator; microdialysis;
D O I
10.1016/j.bios.2004.09.010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Novel planar glucose biosensors to be used for continuous monitoring have been developed. The electrodes are produced with the "screen printing" technique, and present a high degree of reproducibility together with a low cost and the possibility of mass production. Prior to enzyme immobilisation, electrodes are chemically modified with ferric hexacyanoferrate, (Prussian Blue). This allows the detection of the hydrogen peroxide produced by the enzymatic reaction catalysed by GOD, at low applied potential (ca. 0.0 V versus Ag/AgCl), highly limiting any electrochemical interferences. The layer of Prussian Blue (PB) showed a high stability at the working conditions (pH 7.4) and also after 1 year of storage dry at RT, no loss of activity was observed. The assembled glucose biosensors, showed high sensitivity towards glucose together with a long-term operational and storage stability. In a continuous flow system, with all the analytical parameters optimised, the glucose biosensors detected glucose concentration as low as 0.025 mM with a linear range up to 1.0 mM. These probes were also tested over 50-60 h in a continuous flow mode to evaluate their operational stability. A 0.5 mM concentration of glucose was continuously fluxed into a biosensor wall-jet cell and the current due to the hydrogen peroxide reduction was continuously monitored. After 50-60 h, the drift of the signal observed was around 30%. Because of their high stability, these sensors suggest the possibility of using such biosensors, in conjunction with a microdialysis probe, for a continuous monitoring of glucose for clinical purposes. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1993 / 2000
页数:8
相关论文
共 26 条
[11]   INVIVO BEHAVIOR OF HYPODERMICALLY IMPLANTED MICROFABRICATED GLUCOSE SENSORS [J].
KOUDELKA, M ;
ROHNERJEANRENAUD, F ;
TERRETTAZ, J ;
BOBBIONIHARSCH, E ;
DEROOIJ, NF ;
JEANRENAUD, B .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) :31-36
[12]   Continuous subcutaneous glucose monitoring in diabetic patients - A multicenter analysis [J].
Maran, A ;
Crepaldi, C ;
Tiengo, A ;
Grassi, G ;
Vitali, E ;
Pagano, G ;
Bistoni, S ;
Calabrese, G ;
Santeusanio, F ;
Leonetti, F ;
Ribaudo, M ;
Di Mario, U ;
Annuzzi, G ;
Genovese, S ;
Riccardi, G ;
Previti, M ;
Cucinotta, D ;
Giorgino, F ;
Bellomo, A ;
Giorgino, R ;
Poscia, A ;
Varalli, M .
DIABETES CARE, 2002, 25 (02) :347-352
[13]  
Mastrototaro J, 1999, J PEDIATR ENDOCR MET, V12, P751
[14]  
Meyeroff C., 1992, DIABETOLOGIA, V35, P224
[15]   SUBCUTANEOUS MICRODIALYSIS PROBE COUPLED WITH GLUCOSE BIOSENSOR FOR INVIVO CONTINUOUS MONITORING [J].
MOSCONE, D ;
PASINI, M ;
MASCINI, M .
TALANTA, 1992, 39 (08) :1039-1044
[16]  
MOSCONE D, 1993, ANALUSIS, V21, pM40
[17]   Construction and analytical characterization of Prussian Blue-based carbon paste electrodes and their assembly as oxidase enzyme sensors [J].
Moscone, D ;
D'Ottavi, D ;
Compagnone, D ;
Palleschi, G ;
Amine, A .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2529-2535
[18]   DEVELOPING GLUCOSE SENSORS FOR IN-VIVO USE [J].
PICKUP, J .
TRENDS IN BIOTECHNOLOGY, 1993, 11 (07) :285-291
[19]   CLINICIAN REQUIREMENTS FOR CHEMICAL SENSORS FOR INVIVO MONITORING - A MULTINATIONAL SURVEY [J].
PICKUP, JC ;
ALCOCK, S .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (08) :639-646
[20]   A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1) [J].
Poscia, A ;
Mascini, M ;
Moscone, D ;
Luzzana, M ;
Caramenti, G ;
Cremonesi, P ;
Valgimigli, F ;
Bongiovanni, C ;
Varalli, M .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (07) :891-898