Blood flow measurement by magnetic resonance imaging in congenital heart disease

被引:75
作者
Powell, AJ
Geva, T
机构
[1] Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USA
关键词
magnetic resonance imaging; congenital heart disease; blood flow; phase-contrast MRI;
D O I
10.1007/s002469910007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Investigation of blood flow in the heart and vessels may provide insight into the function of the cardiovascular system and aid patient management decisions. Phase velocity cine magnetic resonance imaging (PVC MRI) is a powerful and accurate noninvasive technique to quantitate and analyze blood flow. This article describes the principles, performance, and potential limitations of PVC MRI measurements. Clinical applications of PVC MRI are then reviewed with an emphasis on the assessment of congenital heart disease.
引用
收藏
页码:47 / 58
页数:12
相关论文
共 96 条
[1]   In vivo evaluation of Fontan pathway flow dynamics by multidimensional phase-velocity magnetic resonance imaging [J].
Be'eri, E ;
Maier, SE ;
Landzberg, MJ ;
Chung, T ;
Geva, T .
CIRCULATION, 1998, 98 (25) :2873-2882
[2]   QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
FIRMIN, DN ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 117 (06) :1214-1222
[3]   QUANTIFICATION OF LEFT-TO-RIGHT ATRIAL SHUNTS WITH VELOCITY-ENCODED CINE NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
BRENNER, LD ;
CAPUTO, GR ;
MOSTBECK, G ;
STEIMAN, D ;
DULCE, M ;
CHEITLIN, MD ;
OSULLIVAN, M ;
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (05) :1246-1250
[4]   Visualizing blood flow patterns using streamlines, arrows, and particle paths [J].
Buonocore, MH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) :210-226
[5]   FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING [J].
BUONOCORE, MH ;
BOGREN, H .
MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) :141-154
[6]   CINE PHASE-CONTRAST MR FLOW MEASUREMENTS - IMPROVED PRECISION USING AN AUTOMATED-METHOD OF VESSEL DETECTION [J].
BURKART, DJ ;
FELMLEE, JP ;
JOHNSON, CD ;
WOLF, RL ;
WEAVER, AL ;
EHMAN, RL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (03) :469-475
[7]   RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING [J].
CAPUTO, GR ;
KONDO, C ;
MASUI, T ;
GERACI, SJ ;
FOSTER, E ;
OSULLIVAN, MM ;
HIGGINS, CB .
RADIOLOGY, 1991, 180 (03) :693-698
[8]   MR MEASUREMENT OF BLOOD-FLOW IN THE TRUE AND FALSE CHANNEL IN CHRONIC AORTIC DISSECTION [J].
CHANG, JM ;
FRIESE, K ;
CAPUTO, GR ;
KONDO, C ;
HIGGINS, CB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (03) :418-423
[9]  
Chatzimavroudis GP, 1998, J HEART VALVE DIS, V7, P94
[10]   Slice location dependence of aortic regurgitation measurements with MR phase velocity mapping [J].
Chatzimavroudis, GP ;
Walker, PG ;
Oshinski, JN ;
Franch, RH ;
Pettigrew, RI ;
Yoganathan, AP .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :545-551