Potential clinical impact of variability in the measurement of coronary artery calcification with sequential MDCT

被引:20
作者
Halliburton, SS
Stillman, AE
Lieber, M
Kasper, JM
Kuzmiak, SA
White, RD
机构
[1] Cleveland Clin Fdn, Div Radiol HB6, Sect Cardiovasc Imaging, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH 44195 USA
关键词
D O I
10.2214/ajr.184.2.01840643
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The potential clinical impact of variability in the measurement of coronary artery calcification with sequential MDCT was evaluated using Agatston, volume, and mass scoring algorithms. SUBJECTS AND METHODS. Fifty-six patients were imaged twice using an identical prospectively ECG-triggered sequential scanning protocol. The Agatston, volume, and mass scores were computed by two observers independently. In addition, a patient's total Agatston score was referenced to an age- and sex-stratified database to determine a percentile ranking. Interscan, interobserver, and intraobserver variability and the resultant impact on patients' risk stratifications were assessed. RESULTS. Significant interscan differences were found for all mean coronary calcium scores (Wilcoxson's signed rank test, p < 0.0001). Although the median percentage of interscan variability was low for all scoring methods, the interquartile range was wide, indicating significant variability in the data. Median scores (lower quartile-upper quartile) for observers I and 2, respectively, were as follows: Agatston, 5% (0-79%) and 6% (0-83%); volume, 12% (051 %) and 12% (0-57%); and mass, 14% (0-57%) and 14% (0-58%). Interobserver and intraobserver differences between mean calcium scores were not significant, and consequently, lower interobserver and intraobserver variabilities (narrow interquartile ranges of 0-5%) were observed for all scores. Despite significant interscan differences in calcium scores, the percentile ranking assigned to the two scans differed in only 13% of patients. Interobserver differences resulted in a change in the percentile ranking in 7-9% of patients, whereas intraobserver differences caused a change in only 5% of patients. CONCLUSION. The accuracy of sequential MDCT for coronary calcium quantification is sufficient in most cases for stratification of patient risk.
引用
收藏
页码:643 / 648
页数:6
相关论文
共 21 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP [J].
Becker, CR ;
Kleffel, T ;
Crispin, A ;
Knez, A ;
Young, J ;
Schoepf, UJ ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1295-1298
[3]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[4]   REPRODUCIBILITY OF THE MEASUREMENT OF CORONARY CALCIUM WITH ULTRAFAST COMPUTED-TOMOGRAPHY [J].
DEVRIES, S ;
WOLFKIEL, C ;
SHAH, V ;
CHOMKA, E ;
RICH, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (14) :973-975
[5]   New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging [J].
Flohr, T ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Schaller, S ;
Ohnesorge, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08) :1022-1027
[6]   Age and gender distributions of coronary artery calcium detected by electron beam tomography in 35,246 adults [J].
Hoff, JA ;
Chomka, EV ;
Krainik, AJ ;
Daviglus, M ;
Rich, S ;
Kondos, GT .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (12) :1335-1339
[7]   Coronary artery calcium: Accuracy and reproducibility of measurements with multi-detector row CT - Assessment of effects of different thresholds and quantification methods [J].
Hong, C ;
Bae, KT ;
Pilgram, TK .
RADIOLOGY, 2003, 227 (03) :795-801
[8]   Coronary artery calcium: Absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies [J].
Hong, C ;
Becker, CR ;
Schoepf, UJ ;
Ohnesorge, B ;
Bruening, R ;
Reiser, MF .
RADIOLOGY, 2002, 223 (02) :474-480
[9]   Quantification of coronary artery calcium using multidetector CT and a retrospective ECG-gating reconstruction algorithm [J].
Horiguchi, J ;
Nakanishi, T ;
Ito, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1429-1435
[10]   Determination of coronary calcium with Multi-slice Spiral computed tomography: a comparative study with electron-beam CT [J].
Knez, A ;
Becker, C ;
Becker, A ;
Leber, A ;
White, C ;
Reiser, M ;
Steinbeck, G .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (04) :295-303