Measurement of pulsatile total blood flow in the human and rat retina with ultrahigh speed spectral/Fourier domain OCT

被引:65
作者
Choi, WooJhon [1 ,2 ]
Baumann, Bernhard [1 ,2 ,3 ,4 ]
Liu, Jonathan J. [1 ,2 ]
Clermont, Allen C. [5 ]
Feener, Edward P. [5 ]
Duker, Jay S. [3 ,4 ]
Fujimoto, James G. [1 ,2 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] Tufts Univ, New England Eye Ctr, Boston, MA 02116 USA
[4] Tufts Univ, Tufts Med Ctr, Boston, MA 02116 USA
[5] Joslin Diabet Ctr, Beetham Eye Inst, Boston, MA 02215 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2012年 / 3卷 / 05期
基金
美国国家卫生研究院;
关键词
OPTICAL COHERENCE TOMOGRAPHY;
D O I
10.1364/BOE.3.001047
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present an approach to measure pulsatile total retinal arterial blood flow in humans and rats using ultrahigh speed Doppler OCT. The axial blood velocity is measured in an en face plane by raster scanning and the flow is calculated by integrating over the vessel area, without the need to measure the Doppler angle. By measuring flow at the central retinal artery, the scan area can be very small. Combined with ultrahigh speed, this approach enables high volume acquisition rates necessary for pulsatile total flow measurement without modification in the OCT system optics. A spectral domain OCT system at 840nm with an axial scan rate of 244kHz was used for this study. At 244kHz the nominal axial velocity range that could be measured without phase wrapping was +/- 37.7mm/s. By repeatedly scanning a small area centered at the central retinal artery with high volume acquisition rates, pulsatile flow characteristics, such as systolic, diastolic, and mean total flow values, were measured. Real-time Doppler C-scan preview is proposed as a guidance tool to enable quick and easy alignment necessary for large scale studies. Data processing for flow calculation can be entirely automatic using this approach because of the simple and robust algorithm. Due to the rapid volume acquisition rate and the fact that the measurement is independent of Doppler angle, this approach is inherently less sensitive to involuntary eye motion. This method should be useful for investigation of small animal models of ocular diseases as well as total blood flow measurements in human patients in the clinic. (c) 2012 Optical Society of America
引用
收藏
页码:1047 / 1061
页数:15
相关论文
共 28 条
[11]   Full-range, high-speed, high-resolution 1-μm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye [J].
Makita, Shuichi ;
Fabritius, Tapio ;
Yasuno, Yoshiaki .
OPTICS EXPRESS, 2008, 16 (12) :8406-8420
[12]   Quantitative retinal-blood flow measurement with three-dimensional vessel geometry determination using ultrahigh-resolution Doppler optical coherence angiography [J].
Makita, Shuichi ;
Fabritius, Tapio ;
Yasuno, Yoshiaki .
OPTICS LETTERS, 2008, 33 (08) :836-838
[13]  
Oppenheim A.V., 2009, Discrete-time signal processing, V3rd
[14]   RETINAL BLOOD-FLOW IN DIABETIC-RETINOPATHY [J].
PATEL, V ;
RASSAM, S ;
NEWSOM, R ;
WIEK, J ;
KOHNER, E .
BMJ-BRITISH MEDICAL JOURNAL, 1992, 305 (6855) :678-683
[15]   Imaging pulsatile retinal blood flow in human eye [J].
Rao, Bin ;
Yu, Lingfeng ;
Chiang, Huihua Kenny ;
Zacharias, Leandro C. ;
Kurtz, Ronald M. ;
Kuppermann, Baruch D. ;
Chen, Zhongping .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (04)
[16]   Ocular blood flow and associated functional deviations in diabetic retinopathy [J].
Schmetterer, L ;
Wolzt, M .
DIABETOLOGIA, 1999, 42 (04) :387-405
[17]   Stable absolute flow estimation with Doppler OCT based on virtual circumpapillary scans [J].
Singh, Amardeep S. G. ;
Kolbitsch, Christoph ;
Schmoll, Tilman ;
Leitgeb, Rainer A. .
BIOMEDICAL OPTICS EXPRESS, 2010, 1 (04) :1047-1059
[18]   Quantitative cerebral blood flow with Optical Coherence Tomography [J].
Srinivasan, Vivek J. ;
Sakadzic, Sava ;
Gorczynska, Iwona ;
Ruvinskaya, Svetlana ;
Wu, Weicheng ;
Fujimoto, James G. ;
Boas, David A. .
OPTICS EXPRESS, 2010, 18 (03) :2477-2494
[19]   Velocity-resolved 3D retinal microvessel imaging using single-pass flow imaging spectral domain optical coherence tomography [J].
Tao, Yuankai K. ;
Kennedy, Kristen M. ;
Izatt, Joseph A. .
OPTICS EXPRESS, 2009, 17 (05) :4177-4188
[20]   Phase-resolved optical frequency domain imaging [J].
Vakoc, BJ ;
Yun, SH ;
de Boer, JF ;
Tearney, GJ ;
Bouma, BE .
OPTICS EXPRESS, 2005, 13 (14) :5483-5493