Magnetic resonance-guided placement of atrial septal closure device in animal model of patent foramen ovale

被引:56
作者
Buecker, A
Spuentrup, E
Grabitz, R
Freudenthal, F
Muehler, EG
Schaeffter, T
van Vaals, JJ
Günther, RW
机构
[1] Univ Technol Aachen, Clin Diagnost Radiol, D-52057 Aachen, Germany
[2] Univ Technol Aachen, Clin Pediat Cardiol, D-52057 Aachen, Germany
[3] Univ Kiel, Dept Pediat Cardiol, Kiel, Germany
[4] Philips Res Labs, Hamburg, Germany
[5] Philips Med Syst, Best, Netherlands
关键词
magnetic resonance imaging; catheterization; defects;
D O I
10.1161/01.CIR.0000023621.88708.62
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Percutaneous closure of the patent foramen ovale (PFO) is usually performed under x-ray in combination with ultrasound guidance, We tested the feasibility of applying magnetic resonance (MR) guidance for percutaneous closure of PFO in an animal model, thus avoiding the disadvantage of ionizing radiation. Methods and Results-Real-time MRI with radial or spiral k-space filling (115 frames per second) on an interventional 1.5-T high-field whole-body system was exploited to examine the feasibility of MR-guided closure of the PFO in 7 piglets weighing approximate to 14 kg. A specially designed prototype nonmagnetic closure device was introduced via the femoral vein. The short bore of the magnet and in-room monitors allowed for visualization and steering of the catheter with the loaded occluder. Catheterization of the left atrium and, finally, correct placement of the device was possible in all animals. Deployment of the device was depicted by real-time MR, and initial misplacement, which occurred in 2 animals, was easily detected and corrected. Conclusions-Real-time MR guidance of PFO closure, without the use of ionizing radiation, is feasible in an animal model.
引用
收藏
页码:511 / 515
页数:5
相关论文
共 18 条
[1]  
Berger F, 2000, Z KARDIOL, V89, P1119, DOI 10.1007/s003920070139
[2]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[3]   Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging [J].
Brown, PH ;
Thomas, RD ;
Silberberg, PJ ;
Johnson, LM .
PEDIATRIC RADIOLOGY, 2000, 30 (04) :229-235
[4]   Real-time MR guidance for inferior vena cava filter placement in an animal model [J].
Bücker, A ;
Neuerburg, JM ;
Adam, GB ;
Glowinski, A ;
Schaeffter, T ;
Rasche, V ;
van Vaals, JJ ;
Günther, RW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (06) :753-756
[5]   Real-time-MR guidance for placement of a self-made fully MR-compatible atrial septal occluder:: in vitro test [J].
Buecker, A ;
Spuentrup, E ;
Grabitz, R ;
Freudenthal, F ;
Schaeffter, T ;
van Vaals, JJ ;
Günther, W .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (03) :283-285
[6]   Artifact-free in-stent lumen visualization by standard magnetic resonance angiography using a new metallic magnetic resonance imaging stent [J].
Buecker, A ;
Spuentrup, E ;
Ruebben, A ;
Günther, RW .
CIRCULATION, 2002, 105 (15) :1772-1775
[7]   Transcatheter closure of atrial septal defects without fluoroscopy - Feasibility of a new method [J].
Ewert, P ;
Berger, F ;
Daehnert, I ;
van Wees, J ;
Gittermann, M ;
Abdul-Khaliq, H ;
Lange, PE .
CIRCULATION, 2000, 101 (08) :847-849
[8]  
Godart F, 2000, J MAGN RESON IMAGING, V12, P639, DOI 10.1002/1522-2586(200010)12:4<639::AID-JMRI18>3.0.CO
[9]  
2-W
[10]   Magnetic resonance imaging after percutaneous closure of a patent foramen ovale [J].
Grebe, O ;
Giesler, M ;
Kestler, HA ;
Hombach, V ;
Höher, M .
CIRCULATION, 2001, 104 (22) :E117-E118